First Alert ReadyGuard-RI Quick Start Manual
First Alert ReadyGuard-RI Quick Start Manual

First Alert ReadyGuard-RI Quick Start Manual

Advertisement

Quick Links

ReadyGuard-RI is not intended for UL985 Household Fire applications unless a 24-hour backup battery
U U U U L L L L
(P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed.
Introduction
This Quick Start Guide can help you install the rechargeable ReadyGuard-RI quickly and easily by providing the
basic steps for installation using the built-in defaults. For more detailed information and important notes, refer to
the ReadyGuard-RI Installation and Setup Guide.
The following steps assume that one of the system's default tables will be used.
For programming data values and Powerline Carrier Devices other than those listed in the default tables, see the
Installation Instructions.
Default Table Summary
Zone
2
front door
3
back door
4
window
5
motion detector
6
-------
7
-------
8
-------
9
-------
26
loop 3 arm away
27
loop 2 disarm
28
loop 4 arm stay
29
loop 1 no alarm response
30
loop 3 arm away
31
loop 2 disarm
32
loop 4 arm stay
33
loop 1 no alarm response
92
99
Master User Code
Installer Code
Duress Code
Entering Expert Program Mode: installer code + 8 0 0
Interactive Mode
* 56 Enhanced Zone Programming
* 83 Enhanced Sequential Mode
*84 Assign Zone Voice Descriptors
Exiting Program Mode: * 98 inhibits re-entry into the Programming mode using the Installer Code.
* 99 allows re-entry into the Program mode using Installer Code + 8 0 0.
NOTES:
• Table 4 supports the automatic paging feature (open/close events reported to pager phone number),and a Powerline Carrier Device programmed
as device 8, which closes and stays closed upon burglary alarms and restores after bell timeout. For other applications or actions (e.g., using a
pulsing siren), see the *80 Device Programming Menu Mode section of the Installation Instructions.
• Primary and secondary report format for all tables is Ademco's Contact ID® reporting.
• Tables 1, 3 and 4 record only alarms, alarm restores, troubles, and trouble restores in the event log. Table 2 records all events in the event log.
Table 1
front door
back door
garage door
motion detector
smoke detector
-------
-------
-------
loop 3 arm away
loop 2 disarm
loop 4 arm stay
loop 1 no alarm response
loop 3 arm away
loop 2 disarm
loop 4 arm stay
loop 1 no alarm response
duress
silent alarm
audible alarm
1-2-3-4
4-1-1-2
------
ReadyGuard-RI
Security Systems
Table 2
front door
back door
window
window
window
window
motion detector
smoke detector
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 no alarm response
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 no alarm response
duress
silent alarm
1-2-3-4
4-1-1-2
------
Used to Program
Zone characteristics, report codes, and serial numbers
5800 Series transmitter serial numbers
Voice descriptors for each zone
K14117-1

Quick Start Guide

Table 3
front door
back door
window
window
window
window
motion detector
smoke detector
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 no alarm response
loop 3 arm away
loop 2 disarm
loop 4 close device
loop 1 no alarm response
duress
silent alarm
1-2-3-4
4-1-1-2
------
4/06 Rev. A
Table 4
duress
1-2-3-4
4-1-1-2
------

Advertisement

loading

Summary of Contents for First Alert ReadyGuard-RI

  • Page 1: Quick Start Guide

    (P/N LYNXRCHKIT-HC or LYNXRCHKIT-SHA) is installed. Introduction This Quick Start Guide can help you install the rechargeable ReadyGuard-RI quickly and easily by providing the basic steps for installation using the built-in defaults. For more detailed information and important notes, refer to the ReadyGuard-RI Installation and Setup Guide.
  • Page 2: Installation And Electrical Connections

    Installing ReadyGuard-RI Installation and Electrical Connections Step Action Install the control as follows: Separate the front assembly from the back plate and disconnect the cable from the front assembly board. Note: Disconnect the cable only from the front assembly board, not from the terminal block PC board.
  • Page 3: System Programming

    6-14VDC LOCAL SOUNDER DISABLE 120mA max. SHUNT REMOVE TO DISABLE (e.g. WAVE2EX) SYNC WEEKLY TESTING IS REQUIRED TO ENSURE THE READYGUARD-RI CONTROL IS COMPATIBLE PROPER OPERATION WITH THE FOLLOWING INTEGRAL OF THIS SYSTEM RECHARGEABLE BATTERY PACKS: DATA P/N LYNXRCHKIT-SC NOTE...
  • Page 4 Step Action Enhanced Sequential Mode - Press *83, then follow the prompts as follows: Zone Number - Enter 2-digit zone number of the first transmitter to have its serial number entered. The system will announce the Voice Descriptor for the selected zone number, if it is programmed.
  • Page 5 Step Action Once all 7 digits have been entered, press the [*] key. If less than 7 digits are entered, (Cont.) the keypad will emit a single long beep and return to the (1A) prompt without displaying the “L”. If more than 7 digits have been entered, the first 6 digits will be saved along with the last digit that was entered (entering 123456789 yields the serial number 1234569).
  • Page 6 Keypad Functions (when default programming is used) Security Functions Checking system status: STATUS (high level messages); press STATUS again for secondary messages. To arm in STAY mode: Press and hold down STAY (or enter your code + STAY ) See note below. To restart exit delay: STAY (applies only if system is armed in Stay mode and Quick Exit option has been enabled) To arm in AWAY mode: Press and hold down AWAY (or enter your code + AWAY ) See note below.
  • Page 7 Remote Phone Control Operation To remotely disarm system: + [1] To remotely arm in AWAY mode: + [2] To remotely arm in STAY mode: + [3] To remotely arm in AWAY or STAY with NO DELAY: + [2] or [3] + [0] To remotely activate X10 devices 1-6: [#] + [4] + device no.
  • Page 8 ‡K14117-1EŠ 149 Eileen Way, Syosset, NY 11791 www.firstalertprofessional.com K14117-1 4/06 Rev. A Copyright © 2006 Honeywell International Inc.