Epson Artisan 700/Epson Stylus Photo PX700W/TX700W
C H E C K
P O I N T
DISASSEMBLY/ASSEMBLY
4.2.2 Removing the Housing
4.2.2.1 Scanner Unit
The disassembly/reassembly procedures of Artisan 700/PX700W/
TX700W differ from those of Artisan 800/PX800FW/TX800FW.
See
4.3.1.1 "Scanner Unit (Artisan 700/PX700W/TX700W)" (p185)
for the procedures.
Parts/Components need to be removed in advance:
ADF Unit
Removal procedure
1.
Open the Scanner Unit.
2.
Disconnect the Scanner FFCs (x3) together with the Ferrite Cores (x2) from
the Main Board. (See
Fig.
4-6.)
3.
Pull out the terminal of the Grounding Wire from the fixing rib of the frame.
Grounding Wire
Terminal of Grounding
Wire and the fixing rib
Ferrite cores
Figure 4-6. Removing the Scanner Unit (1)
Disassembly Procedures
Main Board
Scanner FFCs
Double-
sided tape
Revision C
102
Confidential