Part 2: Technical Information

5. ERROR CODE DISPLAY

As with other cameras, you can check the camera's condition in the inhibit
mode. In the camera's inhibit mode, Err XXX is displayed. The user can see five
types of error codes. Using the service adjustment software, you can check the
detailed error codes and also erase error codes.
<User-viewable Errors>
Display XX
01
Lens faulty
02
CF card faulty
04
Folder limit / CF card has
inadequate storage space.
05
Flash pop up error
99
Other defects
<Detailed Error Codes> (Viewable with the adjustment software.)
Error code
1
10000000 00000000 Lens aperture blades does not operate Lens
01000000 00000000 Lens aperture blades is not Lens
00100000 00000000 Lens communication error
00010000 00000000 Mirror up cannot be implemented Mirror box unit
00001000 00000000 Mirror down cannot be implemented Mirror box unit
00000100 00000000 Shutter charge cannot be implemented Mirror box unit
00000010 00000000 Rear screen switch is not turned Shutter unit
00000001 00000000 Completion of charging is not output Shutter unit
00000000 01000000 X-contact does not turn on
00000000 00010000 X-contact is turned on at mirror up Shutter unit
00000000 00001000 Flash cannot be popped up
00000000 00000100 * CGE is open during standby Mirror box unit
00000000 00000010 * Mirror up is short-circuited at standby Mirror box unit
00000000 00000001 * CN2 is open at standby
* When any digit other than the specified digit goes "1", the specific trouble may be
caused by the other error.
In such a case, clear the error once and check the operation again in order to
specify the error.
Description
Contents
2
set in the full open state
after mirror is raised up
off after release
after the pre-illumination
Probable Cause and Countermeasures
• Lens communication error at shutter
release.
• Lens diaphragm does not stop down
at shutter release.
• Lens detection SW does not change.
• CF card connector pin faulty.
• CF card faulty.
• The number of folders created
exceeded the limit.
Delete unnecessary folders.
• Pop-up switch error
• Faulty system, DC/DC fuse blown.
The part that is suspected
as the cause of the error
Lens
Shutter unit
Top cover unit
Shutter unit
2-24
OLC
99