Baxi Bermuda SL3 Fireside Gas Central Heating Unit Comp No. 237883 - Issue 4 – 1/00 Installation and Servicing Instructions Supplied By www.heating spares.co Tel. 0161 620 6677...
Page 2
Bermuda 57/4 E G.C.No 44 077 74 INTRODUCTION This unit is the gas fire section of the Bermuda SL3 central Renewal heating boiler and gas fire. The heat input is 5.70kW (19,450 Btu/h) and the fire is available for use with Gas Type G20 Baxi Bermuda SL3 Renewal (Natural Gas) at 20mbar or Gas Type G31 (Propane).
DAMPERS, ECONOMISERS etc.). without the express written maximum dimensions. permission of Baxi Limited could invalidate the appliance Hearth: If the fire is to be hearth mounted, the hearth must be at warranty and infringe the GAS SAFETY (Installation and Use) least 13mm (½...
Installation Instructions – Page 4 GAS SUPPLY 1. The gas supply is provided from the service tap on the boiler unit. A supply pipe is provided with the fire. This pipe has one flared end for connection to the fire and a plain end which is connected to the service tap by a nut and olive.
Commissioning the Fire – Page 5 1. Remove the polystyrene fitting securing the coal bed (Fig.11) 11. Plug in the electrical supply to the case and fit the controls as follows: cover panel and control knob (Fig.13). Disengage the front panel retaining clamps and remove the glass front panel.
Page 6
Commissioning the Fire – Page 6 Supplied By www.heating spares.co Tel. 0161 620 6677...
Page 7
A.S.D. pilot assembly is possible. The A.S.D. should not be altered to prevent it operating correctly or bypassed in any way. If the A.S.D. has to be replaced only use a Genuine Baxi Spare Part. 11. Replace the parts in reverse order of dismantling, make sure that: The spark gap is as in Fig.
1. GAS CONTROL TAP/FFD (Fig.12) component failure(s). Only use a Genuine Baxi Spare Part. To grease the tap proceed as follows: Pull off the plastic cap and disconnect the spark electrode lead from the Undo the screw retaining the pilot shield and remove the shield.
Short Parts List – Page 12 BAXI BERMUDA SL3 B.G.C. No 37 077 60 Key No Description G.C. Manufact’rs Part No Seal - Glass Frame 155 747 043111 Glass & Frame Assembly 155 758 040955 Knob - Gas Tap Control...
Page 12
Bermuda SL3 Renewal G.C.No 37 075 02A The kit supplied with Renewal appliances provides all the necessary components to fit a Baxi Bermuda SL3 Renewal firefront to the following Bermuda Boilers. The Renewal Fires may be used with the following Boilers:...
Page 13
Existing Fire – Page 14 If the fire is wall mounted remove and discard the existing support frame (Bermuda 401 only). Retain the two support brackets. These will be needed in wall mounting the renewal fire. If the fire is hearth mounted ensure that the base of the builders opening and the front hearth are at the same level.
Page 14
Propane appliances can be converted to operate on Natural Gas if required. A conversion kit. is available, Baxi Part N’~ 247065. Click here for Helplines...