Sony HDR-CX6EK Service Manual page 9

Digital hd video camera recorder
Hide thumbs Also See for HDR-CX6EK:
Table of Contents

Advertisement

1-3-3. Self-diagnosis Code Table
Self-diagnosis Code
Block
Detailed
Function
Code
C
0
4
0
C
1
3
0
C
1
3
0
C
3
2
6
E
2
0
0
E
6
1
1
E
6
1
1
E
6
2
0
E
6
2
0
E
6
2
0
E
6
2
0
E
6
2
1
E
6
2
1
E
6
2
1
E
6
2
2
E
9
1
0
E
9
4
0
Note 1: After repair, be sure to perform "1-5. PROCESS AFTER FIXING FLASH ERROR".
Note 2: Refer to Service Manual, ADJ ("1-3. DESTINATION DATA WRITE").
HDR-CX6EK/CX7/CX7E/CX7K/CX7EK_L2
Symptom/State
0
Non-standard battery is used.
"Memory Stick Duo" is unformatted.
1
"Memory Stick Duo" is broken.
2
Access error
Difficult to adjust forcus
0
(Cannot initialize focus)
0
EEPROM data are rewritten.
Zoom operations fault
0
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
1
initialization of the zoom lens occurred
simultaneously.
Handshake correction function does not
work well. (With PITCH angular
0
velocity sensor output stopped.)
Handshake correction function does not
work well. (With YAW angular velocity
1
sensor output stopped.)
2
Abnormality of IC for steadyshot.
IC for steadyshot and micro controller
3
communication abnormality among.
0
Shift lens initializing failure.
1
Shift lens overheating (Pitch).
2
Shift lens overheating (Yaw).
0
Abnormality of thermistor.
1
Abnormality when flash is being charged.
Fault of writing to or erasing the
0
flashmemory
Use the InfoLITHIUM battery.
Format the "Memory Stick Duo".
Insert a new "Memory Stick Duo".
Remove the power source. Reconnect it again and operate your
camcorder again.
Retry turn the power on by the power switch. If it does not
recover, check the focus MR sensor of lens block (pin qh, qk of
CN5302 on the LD-222 board). If it is OK, check the focus
motor drive IC (IC5404 on the LD-222 board).
Make EEPROM data correct value.
Inspect the lens block zoom MR sensor (pin w;, wa of CN5302
on the LD-222 board) when zooming is performed when the
zoom lever is operated, and the zoom motor drive circuit
(IC5404 on the LD-222 board) when zooming is not performed.
Check both C : 32 : 60 and E : 61 : 10 of the self-diagnosis code.
Inspect PITCH angular velocity sensors (SE7202 on the CM-077
board) peripheral circuits.
Inspect YAW angular velocity sensors (SE7201 on the CM-077
board) peripheral circuits.
Refer to "1-4-1. E : 62 : 02 [Abnormality of IC for Steadyshot]
Occurred".
Inspect the steadyshot circuit (IC5703 on the LD-222 board).
Refer to "1-4-2. E : 62 : 10 [Shift Lens Initializing Failure]
Occurred".
Refer to "1-4-3. E : 62 : 11 [Shift Lens Overheating (Pitch)]
Occurred".
Refer to "1-4-4. E : 62 : 12 [Shift Lens Overheating (Yaw)]
Occurred".
Refer to "1-4-5. E : 62 : 20 [Abnormality of Thermistor]
Occurred".
Checking of flash unit or replacement of flash unit. (Note 1)
Inspect the flash memory (IC2201 on the VC-493 board).
(Note 2)
1-2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
Correction

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hdr-cx7Hdr-cx7eHdr-cx7kHdr-cx7ek

Table of Contents