Electrical-General
1. All FETCO brewers require Ground. Installation without ground may cause a hazard.
2. The electrical diagram with universal wiring instructions is located on the inside of the lower cover.
3. The installation must comply with applicable federal, state, and local codes having jurisdiction at your
location. Check with your local inspectors to determine what codes will apply

Electrical Connection

1. The CBS-2100XTS series models requires hardwire to the terminal block to a, grounded service
2. Verify that the actual voltage at the electrical service connection is compatible with the specifications on the
brewer's serial number label. Make sure the electrical service match the current draw of the equipment.
3. All CBS-2150XTS have a terminal block for connecting the incoming power wires. Consult local codes to
determine if a cord and plug can be installed on factory supplied terminal block equipment, or if the unit must
be hard wired.
4. Access the terminal block for electrical connection by removing the pullout service module on the lower back.
5. A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near
the brewer, and its location and markings known to the operators.
6. The temperature and water tank fill level are pre-set at the factory. There is no need to turn off the heaters
during the installation process. The heaters are disabled by the control board until the tank is full of water.
The heating process will start automatically when the tank has filled.
7. The body of the brewer must be grounded to a suitable building ground.
8. If Cord Connected: Do not use multiple taps for the plug. Consult local codes to determine if a single circuit is
required for the cord and plug installed. Do not use extension cords for commercial food equipment.
9. All covers, removable panels and electrical connections must be secured in-place within the unit to meet
national and local standards.
See wiring diagrams in back of user guide for connections
For cord and plugCBS-2140xts brewers
For electrician
Factory Configuration
120 VAC, 3 wires
GROUND
L1 L2
For hardwire CBS-2140xts brewers
CBS-2140XTS
Wiring
Configuration
GROUND
LUG
GROUND
WIRE
Incoming Power:
Connect wires to L1, L2, Ground
15
208-240 VAC
2 wires + ground
L1 L2
208-240V