Side View; Operating Service Valves - Lennox Merit 13ACD-018 Installation Instructions Manual

Lennox merit series 13 acd units
Hide thumbs Also See for Merit 13ACD-018:
Table of Contents

Advertisement

A
A
OUTDOOR
COIL FAN
tDischarge
Air
COMPRESSOR_
SUCTION
ANDLIQUIDLINE
CONNECTIONS
SIDE VIEW
Model
Number
A
B
13ACD-018
24-1/4 (616)
25-1/4 (641 )
13ACD-024
24-1/4 (616)
25-1/4 (641 )
13ACD-030
24-1/4 (616)
33-1/4 (845)
13ACD-036
24-1/4 (616)
33-1/4 (845)
13ACD-042
28-1/4 (718)
29-1/4 (743)
13ACD-048
28-1/4 (718)
37-1/4 (946)
13ACD-060
28-1/4 (718)
33-1/4 (845)
WARNING
OPTIONAL
UNIT STAND-OFF
KIT
(4) (FIELDqNSTALLED)
SIDE VIEW
I
When servicing or repairing HVAC components, ensure
caps and fasteners are appropriately tightened, Table 1
lists torque values for typical service and repair items.
Table 1. Torque
Requirements
Part
Service valve cap
8 ft.- lb.
Sheet metal screws
16 in.- lb.
Machine screws #10
28 in.- lb.
Compressor bolts
90 in.- lb.
Gauge port seal cap
8 ft.- lb.
USING
MANIFOLD
GAUGE
SETS
Recommended
Torque
11 NM
2NM
3NM
10 NM
11 NM
When checking the system charge, use a manifold gauge
set that features low-loss anti-blow back fittings. See figure
1 for a typical manifold gauge connection setup.
OPERATING SERVICE VALVES
IMPORTANT
These instructions are intended as a general guide and do
not supersede local codes in any way. Consult authorities
who have jurisdiction before installation.
The liquid and suction line service valves are typically used
for removing refrigerant, flushing, leak testing, evacuating,
checking charge and charging,
505366M
01/08
Page 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents