Service And Maintenance; Cleaning - Martin EFX500 User Manual

Mania efx series
Hide thumbs Also See for EFX500:
Table of Contents

Advertisement

Service and maintenance

Mania EFX fixtures require simple routine maintenance. The maintenance
schedule depends heavily on the operating environment. Please consult a
Martin service technician for recommendations.
Refer any service procedure not described here to a qualified technician.
Warning!
Disconnect the fixture from power and allow it to cool for at
least 10 minutes before removing any cover.
C l e a n i n g
Important! Excessive dust, grease, and smoke fluid buildup degrades
performance and causes overheating and damage to the
fixture that is not covered by the warranty. Check and, if
necessary, clean fixtures at regular intervals.
Cleaning the fan and air vents
To maintain adequate cooling, dust must be cleaned from the fan and air
vents periodically.
1. Disconnect the fixture from power and allow it to cool for at least 10
minutes.
2. Loosen the lamp cover release thumbscrew and slide and lift the lamp
cover out of the fixture housing. Let the cover hang on its safety strap.
3. Remove the four torx
screws holding the main
cover (see illustration on
right) and slide and lift
the cover out of the
housing. Let the cover
hang on its safety strap.
4. Remove dust and dirt
from the fan blades and
vent grills using a soft
brush, cotton swab,
vacuum, or compressed air.
5. Reinstall the main cover and lamp cover securely before reapplying
power.
26
Mania EFX user manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Efx700Efx600Efx800

Table of Contents