Example Free Body Diagram Determination of WLL:
The following example shows a free body diagram determination of the working loads for a RoomMatch™ array of RM7005, RM7010,
RM9010, RM9020, and RM12020 modules with a 0-degree frame pitch.
Step 1. Determine the array center of gravity in the X-axis using the equation:
= ∑ X
X
* W
COG
M
M
W
A
(6.51)*(56.7) + (10.69)*(56.7) + (21.08)*(56.7) + (38.8)*(56.7) + (66.69)*(56.7)
X
=
COG
Step 2. Free Body Review. Assuming the front fastener is a pivot point and the rear fastener is bearing the entire load (a conservative
approach), the following free body diagram can be developed for one side of the top module:
Where: X
=
X-axis distance of array COG from reference fastener
COG
X
=
X-axis distance from reference to module COG for module n (n = 1 to 8)
Mn
W
=
Weight of module (example: 56.7 kg)
M
W
=
Weight of total array (example: 283.5 kg)
A
6.51 cm (X
)
M1
10.69 cm (X
)
M2
21.08 cm (X
)
M3
38.80 cm (X
)
M4
66.69 cm (X
)
M5
(283.5)
Where:
Reference fastener
M
= Moment (rotational) force about front module fastener
1
F
= Force applied on rear-module fastener
1
F
= Force applied by total array per side (1/2 of total weight)
COG
X
= X-axis distance from front to rear fastener (15 cm)
1
X
= X-axis distance from array center of gravity to front fastener
COG
= 28.75 cm
Installation and Safety Guidelines