Unit Dimensions Dr180, 240; Minimum Clearances - York SUNLINE MagnaDRY DR180C/E00 Technical Manual

Gas/electric single package
Table of Contents

Advertisement

BLOWER MOTOR
BLOWER
ACCESS
COMPARTMENT
ACCESS
(Auxillary)
48- /4
DOT PLUG
(For pressure
drop reading)
GAS OR
ELECTRIC
HEAT ACCESS
VENT AIR
OUTLET
HOODS
COMBUSTION
AIR INLET HOOD
UNIT BASE RAILS
Shown separately to illustrate
Bottom Duct openings. Power
and Gas Piping Connection
location.
NOTE:
For curb mounted units, refer to the curb hanger
dimensions of the curb for proper size of the
supply and return air duct connections.
FIGURE 12 -UNIT DIMENSIONS DR180, 240 & 300 (FRONT VIEW)
TABLE 39: MINIMUM CLEARANCES
LOCATION
Front
Rear
Left Side (Filter Access)
Right Side (Cond. Coil)
2
Below Unit
3
Above Unit
1. If economizer is factory installed, the unassembled rain hood
must be removed from its ride along position in front of evap.
coil, prior to final installation. The hood kit box is 54" long.
2. Units may be installed on combustible floors made from wood or
class A, B, or C roof covering material.
3. Units must be installed outdoors. Overhanging structures or
shrubs should not obstruct condenser air discharge outlet.
NOTE: A 1" clearance must be provided between any com-
bustible material and the supply air ductwork for a
distance of 3 feet from the unit.
NOTE: The products of combustion must not be allowed to
accumulate within a confined space and recirculate.
54
BLOWER
ACCESS
2 .00
(C) GAS
9-3/4
SUPPLY
ENTRY
7- /8
36- /4
6-3/8
5
46-5/8
CONTROL BOX
ACCESS
5-7/8
35
35- /4
RETURN
AIR
33
2-3/4
2 - /2
(D)
GAS SUPPLY
ENTRY
- /8
2- /2
46-5/8
9- /4
CLEARANCE
36"
24" (Less Economizer)
49" (With Economizer)
24" (Less Economizer)
1
36" (With Economizer)
36"
0"
72" With 36" Maximum
Horizontal Overhang (For
Condenser Air Discharge)
ECONOMIZER / MOTORIZED DAMPER
FIXED OUTDOOR INTAKE AIR AND
POWER EXHAUST RAIN HOODS
(See detail Y)
80- 9/32
COMPRESSOR ACCESS
(See detail X)
(A) CONTROL WIRING
ENTRY
92
DISCONNECT
SWITCH
LOCATION
- /2
(B) POWER
All dimensions are in inches. They are
WIRING ENTRY
subject to change without notice.
Certified dimensions will be provided
BOTTOM SUPPLY
upon request.
AND RETURN
AIR OPENINGS
(See Note)
SUPPLY
3-3/4
AIR
(B) POWER WIRING
ENTRY
8- /8
(A) CONTROL WIRING
ENTRY
9-3/4
TABLE 40: UTILITIES ENTRY
HOLE
OPENING SIZE (DIA.)
1-1/8" KO
A
3/4" NPS (Fem.)
3-5/8" KO
B
3" NPS (Fem.)
C
2-3/8" KO
D
1-11/16" Hole
1. One-inch Gas Piping MPT Required.
2. Opening in the bottom to the unit can be located by the side
in the insulation.
NOTE: Locate unit so that the vent air outlet hood is at least:
• Three (3) feet above any force air inlet located within
10 horizontal feet (excluding those integral to the unit).
• Four (4) feet below, 4 horizontal feet from, or 1 foot
above any door or gravity air inlet into the building.
• Four (4) feet from electric and gas meters, regulators
and relief equipment.
NOTE: All entry holes should be field sealed to prevent rain
water entry into building.
036-21539-003-B-0305
COIL
GUARD
KIT
CONDENSER
COILS
USED FOR
Front
Control Wiring
Bottom
Front
Power Wiring
Bottom
Gas Piping (Front)
Gas Piping (Bottom)
Unitary Products Group
1
1,
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents