Electronic Direct Spark Ignition Wiring Diagram; Millivolt Wiring Diagram - Pentair MiniMax 75 Operation & Installation Manual

Pentair aboveground pool & spa heaters
Hide thumbs Also See for MiniMax 75:
Table of Contents

Advertisement

2 0
MiniMax 100 Electronic Direct Spark Ignition Wiring Diagram
EXTERNAL
BOND LUG
TERMINATE SUPPLY SAFETY GROUND WIRE (GREEN) HERE
GROUND SCREW WITH PAINT CUTTING WASHER
CHASSIS
SHEET METAL
MiniMax 100 Millivolt Wiring Diagram
P/N 471105
MODULE
V2/GRD
V1
TH
SPARK
IGNITER
GRN
WHT
BLUE
GAS VALVE
GRN
1
Compliments of www.poolsandstuff.com
MiniMax 100 ELECTRONIC WIRING DIAGRAM
IF ORIGINAL FACTORY WIRING MUST BE REPLACED, INSTALLER MUST SUPPLY
UL OR CSA (IF CANADA) APPROVED WIRE, 18 GAUGE, 600V, 150˚ C TEMPERATURE RATING.
THERMAL FUSE WIRING MUST BE REPLACED WITH UL OR CSA (IF CANADA) APPROVED
WIRE, 18 GAUGE, 600V, 150˚ C TEMPERATURE RATING..
INTERCONNECTING WIRING TO APPLIANCE MUST CONFORM TO THE NATIONAL ELECTRICAL
CODE OR SUPERCEDING LOCAL (WIRING) CODES.
THERMAL
HI LIMIT SW.
FUSE
WHT
WHT
WHT
WHT
ORN
ORN
ON/OFF SW.
2
3
4
Installation (contd.)
WATER
PRESSURE SW.
WHT
WHT
H
N
WHT
ELECTRONIC
THERMOSTAT
TRANSFORMER WIRING :
115V CONN
LINE :
1
& 2 (TIED)
LINE :
3
& 4 (TIED)
230V CONN
2
& 3
(TIED)
LINE :
1
LINE :
4
Remote Wiring Hook-up
The MiniMax 100 may be
connected to a two wire remote
control by disconnecting the wire
connector from the hot
(transformer) side terminal of the
"ON/OFF" switch and connecting
the two wire remote across the end
of this wire and the aforementioned
terminal.
NOTE
When connecting a remote control
to the MiniMax 100 you must install
the low voltage remote control
wires in a separate conduit from
ANY line voltage wires. Do not
exceed 25 ft. wire run for remotes
on millivolt models.
Rev. H 10-16-07

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Minimax 100

Table of Contents