MASTERTEMP
DIRECT AIR INTAKE DUCT WITH 3-INCH PVC PIPE KIT
®
MASTERTEMP
HEATER [KIT P/N 461031)
®
MASTERTEMP
125 HEATER [KIT P/N 474845)
®
MAX-E-THERM
HEATER [KIT P/N 475002)
FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESULT IN
SERIOUS BODILY
INJURY OR DEATH. THIS PRODUCT SHOULD BE INSTALLED AND SERVICED
ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL. INSTALLERS, POOL
OPERATORS AND OWNERS MUST READ THESE WARNINGS AND ALL
INSTRUCTIONS IN THE HEATER INSTALLATION AND USER'S GUIDE BEFORE
USING THIS PRODUCT. THESE INSTRUCTIONS MUST BE LEFT WITH THE
POOL OWNER.
Warnings and safety instructions for Pentair Aquatic Systems pumps and other
related products are available at: http://www.pentairpool.com/safety-warnings
Call (800) 831-7133 for additional free copies of these instructions.
READ AND FOLLOW ALL INSTRUCTIONS - SAVE THESE INSTRUCTIONS
Direct Air Intake Duct with 3-inch PVC Pipe (Indoor Installation)
For indoor heater installations where combustion air supply might be insufficient, the MasterTemp
and Max-E-Therm
air is drawn through 3" PVC duct directly into the heater, PVC pipe can be installed in accordance
with the following requirements:
The air intake opening MUST be installed at least 1 ft. above the roof line or normal snow levels for
free air flow. The Category I or III exhaust vent termination cap must have at least 3 ft. minimum
vertical clearance from air intake duct. See diagram on next page.
Air Intake Kit Contents
•
Adapter -1, Vent Cap-1, 3" PVC pipe-1 (attached to adapter from manufacturing), 3" PVC Union-1
•
#8 Self-Tapping Screws (qty.5), Installation instructions.
P/N 474441.C
®
& MAX-E-THERM
INSTALLATION INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
®
heaters are certified for a direct air intake duct using 3-inch PVC pipe. If outside
®
HEATER
1
®