PWB ASSEMBLY (MAIN)
220 - 240V~
RED
YELLOW
(1)
WASH HEATER TROUBLE
When checking the voltage between
connector
the PWB assembly (Main)
during cotton 95°C washing ,Is the voltage
~
220 - 240V
?
YES
After power off,is the resistance of wire
(RED-YELLOW) connectors between
10
to 30 ?
NO
After power off and the heater terminal is
disconnected, is the resistance 10 to 30 ?
HEATING CONTINUOUSLY ABOVE
THE SETTING WATER TEMPERATURE
Red
YES
When checking thermistor on the tub,
is the thermistor loosened above 2mm from
the rubber?
YES
3
1
2
(1)
3
4
30
Replace the PWB
NO
assembly (Main)
Normal
Replace the heater
NO
assembly
Replace the thermistor
NO
(6322FR2046C)
Push the thermistor
YES
tightly to the rubber.