340102.04 M2C5D506/M309 EN

Checking and cleaning the raw water strainer

Daily, before starting.
VD00125
Checking the raw water strainer
Check daily whether there is any dirt in the

raw water strainer.

14-04-2005
10:34
Pagina 25
CT30119
Cleaning the strainer
Close the seacock before removing the lid
of the water strainer.
Clean the raw water strainer as often as is
necessary, depending on the pollution of
the waterways, but at least once every 6
months. A clogged raw water strainer will
result in excessive temperatures or over-
heating of the engine coolant.
Maintenance
Check the sealing between the lid and
housing after cleaning and re-assembling
the strainer. An improperly sealed lid will
result in air sucked in by the sea water
pump which again will result in overheat-
ing of the engine.