Baxi 35/60 User Operating Instructions Manual page 4

Gas fired wall mounted system boilers
Table of Contents

Advertisement

30° 40° 50° 60° 70° 80°
1
Fig. 3
4
5
30° 40° 50° 60° 70° 80°
10
4
2
bar
2
3
6
7
8
9
11
12
13
2.0 Introduction
2.1
Introduction
1. Your Baxi System 35/60 or 60/100 is a gas
fired, room sealed, powered flue boiler, providing
central heating and hot water for your home. It is
fully automatic and does not have a pilot light.
2.2
Facia Panel
1. The facia panel is behind the hinged lower
door. As well as the On/Off/Reset selector
switch, central heating temperature control knob
and pressure gauge, the facia incorporates ten
neon indicator lights.
2. Neons 10 to 13 indicate the operational status
of the boiler. Neons 4 to 9 have a dual function,
indicating the temperature of the central heating
water when constantly illuminated. If a fault
develops the appropriate neon will begin to
flash. Refer to Sections 3.3 to 3.7.
KEY TO FACIA PANEL (Fig. 3)
1. On/Off/Reset Selector Switch
2. Central Heating Temperature Control
3. Central Heating System Pressure Gauge
Neon Indicators
4. Flame Failure
5. Safety Thermostat Activated
6. Fault on Fan or Flue
7. Fault on Pump or Low System Pressure
8. Fault on Hot Water Sensor
9. Fault on Central Heating Sensor
10. Power On
11. Hot Water Mode
12. Central Heating Mode
13. Burner On
When neons 4 to 9 are constantly illuminated,
they indicate the temperature of the central
heating water.