Fireplace And Framing Specifications - Lennox Elite ELDV-35NM Installation Instructions Manual

Eldv direct-vent elite series
Hide thumbs Also See for Elite ELDV-35NM:
Table of Contents

Advertisement

FIREPLACE AND FRAMING SPECIFICATIONS

Framing
Framing Dimensions
Model No.
A
in.
35-9/16
ELDV35
mm
903
in.
40-9/16
ELDV40
mm
1030
in.
45-9/16
ELDV45
mm
1157
Efficiencies %
Natural Gas
Models
P4
Steady
State
ELDV-35
47
65
EDLV-40
48
68
ELDV-45
49
66
Vent Size
Co-axial DV
4-1/2" Inner
Vent Size
7-1/2" Outer
Notes
Diagrams, illustrations and photo-
graphs are not to scale – consult
installation instructions. Product
designs, materials, dimensions,
specifications, colors and prices are
subject to change or discontinuance
without notice.
F
G
TOP VIEW
M
N
L E
L E
L E
Figure 13
10
B
C
D
40-5/16
21-7/16
56-1/2
1024
545
1435
40-5/16
21-7/16
56-1/2
1024
545
1435
40-5/16
21-7/16
56-1/2
1024
545
1435
Propane
AFUE
P4
Steady
AFUE
State
63
47
68
66
66
53
66
64
64
47
67
65
Input (BTU/HR) - MV & Electronic
Natural & Propane Gas
Models
Input Rate (BTU / HR)
ELDV35N
27,000
ELDV35P
26,000
ELDV40N
29,000
ELDV40P
27,000
ELDV45N
30,000
ELDV45P
28,000
7-5/8
(194)
FLUE OUTLET
A
- 41/2 (114)
COMBUSTION AIR
- 71/2 (190)
10-1/2
(267)
d o
l e
A
B
. o
. n i
0 4
1
8 /
7 3
1
8 /
D
V
5 3
m
m
0 1
1 9
9
3 4
. n i
0 4
1
8 /
7 3
1
8 /
D
V
0 4
m
m
0 1
1 9
9
3 4
. n i
0 4
1
8 /
7 3
1
8 /
D
V
5 4
m
m
0 1
1 9
9
3 4
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Vent Framing - Top Vent
With One 90° Elbow
B
1/2
Inches (millimeters)
Vertical Venting Through the Ceiling:
Frame ceiling opening - Use a plumb line from the ceiling above the appliance to
locate center of the vertical run. Cut and/or frame an opening, 10-1/2" x 10-1/2" (267
mm x 267 mm) inside dimensions, about this center mark (see Figure 18).
E
C
D
FRONT VIEW
C
D
E
F
5 2
5
8 /
9 2
1
8 /
5 3
1
8 /
1 2
1
2 /
6
1 5
7
0 4
8
2 9
5
6 4
5 2
5
8 /
4 3
1
8 /
0 4
1
8 /
6 2
1
2 /
6
1 5
8
7 6
0 1
9 1
6
5 7
5 2
5
8 /
9 3
1
8 /
5 4
1
8 /
1 3
1
2 /
6
1 5
9
4 9
1 1
6 4
8
2 0
10-1/2
)
(
267
5-1/8
(130)
D
C
A
A
C is the required framing depth dimension when the fin-
ish material (drywall) thickness is 1/2 in. (13mm)
NOTE: - The gas is to be stubbed in from the left side ONLY.
EYEBROW HOOD
(OPTIONAL)
B
H
GAS INLET
(LEFT SIDE ONLY)
2-1/4
(57)
G
H
0 1
3
4 /
2 3
1
2 /
35" Model
2
3 7
8
5 2
3 1
3
4 /
2 3
1
2 /
40" Model
3
7 3
8
5 2
45" Model
5 1
3
4 /
2 3
1
2 /
4
1 0
8
5 2
Framing should be
constructed of 2x4 or
larger lumber
7
(178)
12-1/8
(308)
20-15/16
(532)
1(25.4)
ELECTRICAL
INLET
6-1/2 (165)
RIGHT SIDE VIEW
Viewable Glass Size
29-1/4" Wide
20-1/4" High
34-1/4" Wide
25-1/4" High
39-1/4" Wide
25-1/4" High

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents