Model name
YORK
Number of row
Fin spacing
Fin material
Outdoor coil
Tube outside diameter
Tube material
Coil length x height x width
Number of circuit
Type
Capacity
Input
Compressor
Rated current(RLA)
Thermal protector
Refrigerant oil
Input
Output
Outdoor fan
motor
Running current
Speed
Outdoor air flow
Outdoor noise level (Sound power level)
Outdoor noise level
(Sound pressure
level)
Unit (WxDxH)
Outdoor
dimension
Packing (WxDxH)
Outdoor
weight
Gross
Type
Refrigerant
Charge
Liquid side
Gas side
Refrigerant
Max. refrigerant pipe length
pipe
Max. difference in level
Operation temperature range
Ambient temperature range (Cooling)
Ambient temperature range (Heating)
Application area
Unit
Outdoor
Indoor
mm
mm
mm
W/h
ml
rpm
m3/h
dB(A)
dB(A)
mm
mm
Net
kg
kg
mm
mm
m2
2
1.4
Hydrophilic Aluminium
7.94
Inner Grooved copper tube
792x38.1x995
9
Rotary
33718.464
3010
9.3
120
W
870
A
257
142
1.1
W
850
W
4200
A
73
59
1008×410×830
1130×490×930
82
93
R410A
2850
9.52
19.05
g
50
30
16 30
m
-10 46
m
-15 24
82
-10 46
-15 24
65
12
2
1.5
Hydrophilic Aluminium
7.94
Inner Grooved copper tube
970x38.1x1200
10
Rotary
47710.944
4270
12
120
1400
120
100
0.4
930
6500
75
60
948×340×1250
1095×410×1400
96
106
R410A
3300
9.52
19.05
50
30
16 30
-10 46
-15 24
100
-10 46
-15 24
82

Advertisement