(8) Bring lens of QV-5000SX close to the center of ND filters, then stick QV-5000SX and filters
together.
(9) Press the shutter button.
(10) When SENS ADJ COMPLETE is displayed the adjustment of sensitivity is completed.
(11) Turn power switch off.
• When using kenko light box handy 5000 go on with the procedure listed below, 12. to 15.
Execute them only once. If you execute more than once start from procedure 1.
(12) Set function switch to PLAY mode, then turn on power.
(13) Connect QV-5000SX and PC with a link cable then execute R, BGAIN compensation software
(kadj1E.exe) on Windows 95.
(14) Click "replace AD".
(15) White balance adjustment is completed when "AD replacement complete" is displayed.
4. Checking Adjustment
(1) White balance
• Set white balance manually to sunlight.
• Turn on the power switch of simplified viewer and take a picture.
• Compare it with a regular picture and if there are no difference, its setting is OK.
(2) Sensitivity
• Set strobe to AUTO.
• Take a picture of a person's face in a dark room at a distance of about 1 meter.
• Compare it with a regular picture and if there are no difference, its setting is OK.
• Since the intensity of light and color temperature varies in the simplified viewer, let it sit for 30
minutes before using.
• The deviation of simplified viewer's illuminace face's point light intensity is large, try to set the
illuminace face at the center.
• Pay attention since the figure of R, BGAIN compensation software (kadj1E. exe) keeps changing.
Equipment needed to execute white balance and sensitivity adjustment
ADJ SOFT
No. 1
CCD RGB ADJUST
No. 2
CCD SENS ADJUST
PRECAUTIONS
Light source (viewer)
Color temperature
(K) light source 1
(cd/m
4400 ± 200
— 6 —
Light intensisty
2
) light source 2
No specified figure for
light intensity
50 ± 5
No specified figure for
color temperature
Note