Recommended Minimum Service Clearances
Front
28" / 700 mm
Fig. 10
Minimum Clearances to Combustibles
Top
Front
Rear
0 0 AL, CL
0
AL= Alcove
CL= Closet
*1
Refer to the Installation Instructions of the Vitodens 200-W, WB2B Venting System for details.
Please note:
The Vitodens boiler has passed the zero inches vent clearance to combustibles testing requirements dictated by the Harmonized Standard
ANSI Z21.13. CSA 4.9.2000 and therefore is listed for zero clearance to combustibles when vented with a single wall special venting
system (AL-29-4C material). The zero inches vent clearance to combustibles for the Vitodens boiler supercedes the clearance to
combustibles listing that appears on the special venting system label.
Side
12" / 305 mm
Top
12"/305 mm
Side
0"/mm
*1
Left
Right
Vent pipe
0
0
0
Back
0"/mm
Minimum Clearances
9