8 APPENDIX
8.5

BTu specifications

The following tables contain information on measured current consumption as well as calculated heat dissipation
at three states: 1) Stand-by/idling; 2) Normal operation (1/8 of rated power); and 3) at extreme heavy duty
operation (Max. power).
Level
Standby w. remote Power Off via NomadLink
Power On, Idling
1/8 of
rated
power
(Pink noise,
12 dB crest
factor)
Max.
power
(Pink noise,
6dB crest
factor)
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct.
specified here is what is known as the "Active Power" in the amplifier providing useful, real-world values of power consumption and heat
dissipation.
*2) Current draw figures measured at 230 V. 115 V figures are 230 V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features kicks in. Typically this is between 1/4 and 1/3 of rated
power. Note that the max. power condition is very extreme and will never occour during normal operation. Also note that the mains breaker will
not be tripped even it's in excess of max. ratings.
Level
Standby w. remote Power Off via NomadLink
Power On, Idling
1/8 of
rated
power
(Pink noise,
12 dB crest
factor)
Max.
power
(Pink noise,
6dB crest
factor)
Mains connector, 230 V CE version
Mains connector, 115 V ETL version
*1) The amplifier's PSU operates as a non-resistive load, so the calculation "Volts x Amps = Watts" would not be correct.
specified here is what is known as the "Active Power" in the amplifier providing useful, real-world values of power consumption and heat
dissipation.
*2) Current draw figures measured at 230V. 115V figures are 230V figures multiplied by two.
*3) Figures measured at maximum power before amplifier protection and limiter features kicks in. Typically this is between 1/4 and 1/3 of rated
power. Note that the max. power condition is very extreme and will never occour during normal operation. Also note that the mains breaker will
not be tripped even it's in excess of max. ratings.
8 C Series Operation Manual
Rated
Load
power
115VAC 230VAC
1200 x4
8 Ω / Ch.
2400 x2
16 Ω / Bridged
1700 x4
4 Ω / Ch.
3400 x2
8 Ω / Bridged
1200 x4
2 Ω / Ch.
2400 x2
4 Ω / Bridged
1600 x4
100V / Ch.
3200 x2
200V / Bridged
1200 x4
8 Ω / Ch.
2400 x2
16 Ω / Bridged
*3)
1700 x4
4 Ω / Ch.
3400 x2
8 Ω / Bridged
4 Ω / Ch.
1200 x4
8 Ω / Bridged
2400 x2
100V / Ch.
1600 x4
200V / Bridged
3200 x2
16 A, CEE7
20 A / 5-20P
Rated
Load
power
1000 x4
8 Ω / Ch.
16 Ω / Bridged
2000 x2
1200 x4
4 Ω / Ch.
2400 x2
8 Ω / Bridged
2 Ω / Ch.
600 x4
4 Ω / Bridged
1200 x2
900 x4
100V / Ch.
1800 x2
200V / Bridged
1000 x4
8 Ω / Ch.
2000 x2
16 Ω / Bridged
*3)
4 Ω / Ch.
1200 x4
8 Ω / Bridged
2400 x2
600 x4
4 Ω / Ch.
1200 x2
8 Ω / Bridged
100V / Ch.
900 x4
200V / Bridged
1800 x2
16 A, CEE7
20 A / 5-20P
C 68:4
Line Current
Watt
*1)
In
Out
Dissipated
0
0
133
0
Amp (I)
W
*2)
16,0
8,0
1123
600
22,4
11,2
1578
850
21,2
10,6
1378
600
21,0
10,5
1463
800
32,6
16,3
2429
1600
38,8
19,4
2697
1700
35,2
17,6
2296
1200
1096
35,4
17,7
2605
1600
1005
C 48:4
Line Current
Watt
*1)
115VAC 230VAC
In
Out
Dissipated
0
0
123
0
Amp (I)
W
*2)
13,8
6,9
945
500
17,4
8,7
1171
600
12,4
6,2
769
300
13,2
6,6
840
450
28,2
14,1
2116
1333
30,6
15,3
2168
1200
21,6
10,8
1368
600
26,4
13,2
1827
1200
Thermal Dissipation
BTU/hr
kCal/hr
0
0
0
133
454
114
523
1784
450
728
2484
626
778
2655
669
663
2262
570
829
2829
713
997
3402
857
3740
942
3429
864
Instead, measured and
Thermal Dissipation
BTU/hr
kCal/hr
0
0
0
123
420
106
445
1518
383
571
1948
491
469
1600
403
390
1331
335
783
2670
673
968
3303
832
768
2620
660
627
2139
539
Instead, measured and

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

C 48:4C 28:4C 16:4

Table of Contents