Panasonic PT-TW230U Service Manual page 53

Hide thumbs Also See for PT-TW230U:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
9 CB - GAIN AREA V START
10 CR - GAIN AREA H START
11 CR - GAIN AREA V START
12 Image AREA H WIDTH
13 Image AREA V HIGHT
14 Y - OFFSET TARTGET
15 CB OFFSET TARGET
16 CR OFFSET TARGET
17 Y - GAIN TARGET
18 CB - GAIN TARGET
19 CR - GAIN TARGET
20 OFFSET torelance
21 GAIN torelance
Group
CUSTOM(Aspect)
270
0 Scaler Horizontal
1 Scaler Vertical
2 Connect
3 Position Horizontal
4 Position Vertical
5 Aspect Enable
Group
AutoPC Adjust
280
0 AutoPCAdjustEnable
1 Frequency Step
2 Frequency Threshold
3 Fine Phase
4 BLKDET
5 PHASEMSK
Group
Panel Type
290
0 GammaL/R-View
1 GammaL/R-Change
Group
Model No. Setting [No Name]
430
0 Model No. Confirm
1 Model No. Setting
Group
Model No. Setting [PT-TW230 / PT-TW231R]
431
0 Model No. Confirm
1 Model No. Setting
Group
Model No. Setting [PT-TW230U / PT-TW231RU]
432
0 Model No. Confirm
1 Model No. Setting
Group
Model No. Setting [PT-TW230E / PT-TE231RE]
433
0 Model No. Confirm
1 Model No. Setting
Group
Model No. Setting [PT-TW230EJ / PT-TW231EJ]
434
Function
YCBCR Level Acquiring Area
YCBCR Level Acquiring Area Height
Torelance of OFFSET Adj.
Torelance of GAIN Adj.
Scaler Horizontal
Scaler Vertical
0:Individual 1:Normal
Position Horizontal
Position Vertical
TRUE:Enable FALSE:Disable
Auto-PC Adj Operation Enable
if Un-supported Signal Input
Frequency Steps of TotalDot
Total Dot Frequency Threshold
Do Phase Adj after Total Dot
Adj.
Black Level Detection Area
Phase Detection Filter
Sets L-Turn Gamma if the Value
is set to 0.
Sets R-Turn Gamma if the
Value is set to 20.
0:No Name
1:PT-TW230 / PT-TW231R
2:PT-TW230U / PT-TW231RU
3:PT-TW230E / PT-TW231RE
4:PT-TW230EJ / PT-TW231REA
5:PT-TW230EA / PT-TW231REA
6:PT-TW230EAJ / PT-TW231REAJ
7:PT-XW23ST / PT-XW25SR
Model No. is set when the value
is set 0 to 10.
* Refer to S430-0
Model No. is set when the value
is set to 10.
* Refer to S430-0
Model No. is set when the value
is set to 10.
* Refer to S430-0
Model No. is set when the value
is set to 10.
Initial
500
700
500
13
9
4
128
128
217
237
237
1
1
100
100
0
100
100
0
0
1
5
1
1
0
0
10
0
0
0
0
0
0
0
0
-53-
Range
Note
0 - 1000
0 - 1000
0 - 1000
0 - 4095
0 - 4095
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
1 - 255
1 - 255
68 - 132
68 - 132
0 - 1
85 - 115
85 - 115
0 - 1
0 - 1
0: Enable, 1: Disable
0-3
0 - 10
0 [] <--- -----> 10[Not matched]
0: Executes Fine Phase, 1: Not
0 - 1
Execute
0 - 7
0: Effective All Bit,
1: Disable Lower 1 bit
0 - 3
2: Disable Lower 2 bit, 3: Disable
Lower 3 bit
0: Gamma for L-Turn
0-20
20: Gamma for R-Turn * Read
only
0-20
-
0 - 10
-
0 - 10
-
0 - 10
-
0 - 10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-tw231ruPt-tw231rePt-tw231reaPt-tw230ePt-tw230ea

Table of Contents