Panasonic PT-TW230U Service Manual page 51

Hide thumbs Also See for PT-TW230U:
Table of Contents

Advertisement

Electrical Adjustments
Group/
Item Name
Item
Group
Fan Temp Error Setting
253
(Memorized)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
Temp C Warning (Nor-
7
mal)
8 Temp B-A Warning
(Normal)
9 Temp C-A Warning
(Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco) Temp. C-A to judge the Temp
15 Temp A Warning Offset
(Temp)
16 Temp B Warning Offset
(Temp)
17 Temp C Warning Offset
(Temp)
Temp B-A Warning Offset
18
(Temp)
19 Temp C-A Warning Offset
(Temp)
Temp A Warning Offset
20
(Time)
21 Temp B Warning Offset
(Time)
22 Temp C Warning Offset
(Time)
Temp B-A Warning Offset
23
(Time)
24 Temp C-A Warning Offset
(Time)
Group
Fan Control Range Setting (Temp./Voltage)
254
10 High Fan Control Min
Temp
11 High Fan Control Max
Temp
12 High Fan1 Min
13 High Fan1 Max
14 High Fan2 Min
15 High Fan2 Max
16 High Fan3 Min
17 High Fan3 Max
20 Eco Fan Control Min
Temp
21 Eco Fan Control Max
Temp
22 Eco Fan1 Min
23 Eco Fan1 Max
24 Eco Fan2 Min
25 Eco Fan2 Max
26 Eco Fan3 Min
27 Eco Fan3 Max
Group
Fan Start/Cooling Setting
255
0 Fan1 Initial Volt
1 Fan2 Initial Volt
2 Fan3 Initial Volt
4 Fan1 Cooling Speed
5 Fan2 Cooling Speed
6 Fan3 Cooling Speed
8 Cooling Time L1
9 Cooling Time L2
Function
Temp. A to judge the Temp Error
at Normal (Room)
Temp. B to judge the Temp Error
at Normal (Panel)
Temp. C to judge the Temp Error
at Normal (Lamp)
Temp. B-A to judge the Temp
Error at Normal (Clogging Det.)
Error at Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased
XC at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp
mode
Offset of Temp Error (Minutes)
Error Setting Value is increased
X minute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp
mode
Temp Senser Control Start/End
Tem.p at Eco
Fan voltage value at Eco (unit:
0.1V)
Fan Start Voltage (0.1V)
Fan Start Voltage (0.1V)
Power off :Fan Voltage(0.1V)
Power off :Fan Voltage(0.1V)
Power off :Fan Voltage(0.1V)
Cooling Time setting at Fan
Mode L1 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
Cooling Time setting at Fan
Mode L2 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
Initial
HiLand
HiLand
Normal
Ceiling
Normal
Ceiling
(OFF)
(OFF)
(ON1/
(ON1/
ON2)
ON2)
43
43
0/40
0/40
52
52
0/52
0/52
60
60
0/55
0/55
100
100
100/100 100/100
100
100
100/100 100/100
42
42
0/40
0/40
54
54
0/50
0/50
60
60
0/52
0/52
100
100
100/100 100/100
100
100
100/100 100/100
5
5
10
0
0
3
3
3
3
3
Hiland
Hiland
Normal
Ceiling
Normal
Ceiling
(OFF)
(OFF)
(ON1 DIF/
(ON1 DIF/
ON2)
ON2)
35
35
0/32
0/32
40
40
0/38
0/38
65
65
-10/125 -10/125
135
135
0/135
0/135
65
65
-10/90
-10/90
120
120
0/135
0/135
77
77
-5/85
-5/85
90
90
-5/100
-5/100
36
36
0/32
0/32
39
39
0/38
0/38
45
45
-10/110 -10/110
120
120
0/120
0/120
50
50
-10/85
-10/85
100
100
0/100
0/100
55
55
-5/60
-5/60
65
65
-5/80
-5/80
50
50
50
45
60
135
2
3
-51-
Range
Note
30 - 100
30 - 100
30 - 100
0 - 100
0 - 100
30-100
-
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-5
0-5
0-5
0-5
0-5
20 - 100
20 - 100
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
0 - 255
20-100
20-100
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
1-15
1-15

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pt-tw231ruPt-tw231rePt-tw231reaPt-tw230ePt-tw230ea

Table of Contents