Get to Know Your water heater - Gas Models
a vent pipe–exhaust
B vent terminal–exhaust
c Intake or combustion air pipe
d Intake or combustion air terminal
e vent adapter
f Blower assembly
G cold water Inlet
h Inlet water shut-off valve
I
union

tYpIcal InstallatIon

j Inlet dip tube
K anode**
l hot water outlet
M outlet receptacle (115 vac)
n temperature-pressure relief valve
o flue
P Flue Baffle Assembly**
q Insulation
r rating plate
s
Gas supply
* all pIpInG MaterIals to Be supplIed BY custoMers.
** located under the Blower asseMBlY.
*** not pIctured
*cautIon: 115 vac
control harness
InsIde outer jacKet
tYpIcal hot surface IGnIter & MaIn Burner
hot
surface
IGnIter
fIGure 1.
6
t
Manual Gas shut-off valve
u
Ground joint union
v
drip leg (sediment trap)
w
drain valve
X
Gas control valve
Y drain pan
Z
Inner door
aa outer door
BB
hsI Burner assembly***
cc
fv sensor assembly
flaMe
sensor
teMperature IndIcators
teMperature adjustMent Buttons