14. SOFTWARE RESET TABLE
Before hitting the software reset button, record your thermostat's programs and settings in the table
provided below.
HEAT
COOL
DAY
PERIOD
TIME
TEMP. TIME
TEMP.
MORN
DAY
MON
EVE
NIGHT
MORN
DAY
TUES
EVE
NIGHT
MORN
DAY
WED
EVE
NIGHT
15. JUMPER AND SWITCH POSITIONS
--
BATTERY
GAS/ELECTRIC
SWITCH
TERMINALS
E
C
Y1
R
Y2
W
B
O G
REAR OF THERMOSTAT WITH COVER REMOVED
WARNING: Use Energizer
®
or DURACELL
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
2/11/05
12:25 PM
Page 16
HEAT
COOL
DAY
PERIOD
TIME
TEMP. TIME
TEMP.
MORN
DAY
THURS
EVE
NIGHT
MORN
DAY
FRI
EVE
NIGHT
MORN
DAY
SAT
EVE
NIGHT
MORN
DAY
SUN
EVE
NIGHT
+
COMPARTMENT
J7 J6 J5 J4 J3
JUMPERS
MOUNTED
ON
OPEN
CLOSED
CURCUIT
2min
5min
J3
BOARD
24hr
12hr
J4
C
F
J5
S/R On
S/R Off
J6
Overrun
Overrun
J7
Enable
Disable
®
Alkaline Batteries Only.
16
PSPHA732 SERIES
SMART TEMP
®
ELECTRONIC THERMOSTAT
INSTALLATION AND OPERATING INSTRUCTIONS
PM
SET
SUNDAY
WEEKDAY
PROGRAM
DAY/TIME
SET
Installs Easily
Set Day & Time
Choose Heat or Cool
IMPORTANT!
• Please read all instructions carefully before beginning
installation. Save them for future reference.
• Before removing any wiring from your existing thermostat,
its wires must be labeled with their terminal designations.
• Ignore the color of the wires since they may not comply
with any standard.
1.
COMPATIBILITY . . . . . . . . . . . . . . . 2
2.
FEATURES . . . . . . . . . . . . . . . . . . . 2
3.
ELECTRICAL RATINGS . . . . . . . . . . 2
4.
INSTALLATION. . . . . . . . . . . . . . . . 3
4.1.
TOOLS REQUIRED . . . . . . . . . . . . . . 3
4.2.
LOCATION . . . . . . . . . . . . . . . . . . . 3
4.3.
REMOVAL OF OLD UNIT . . . . . . . . . 3
4.4.
MOUNTING. . . . . . . . . . . . . . . . . . . 3
4.5.
WIRING . . . . . . . . . . . . . . . . . . . . . 4
4.5.1. TERMINAL DESCRIPTIONS. . . . . . . . 4
4.5.2. CONNECTING THE WIRES . . . . . . . . 4
4.5.3. COMPLETING YOUR INSTALLATION . 4
5.
OPERATING BASICS . . . . . . . . . . . 5
5.1.
UP/DOWN CHANGE KEYS . . . . . . . . 5
5.2.
SET DAY AND TIME . . . . . . . . . . . . 5
5.3.
TEMPERATURE CONTROL MODES . . 5
5.4.
EMERGENCY (EMER) . . . . . . . . . . . . 5
5.5.
AUTOCHANGE (AUTO) . . . . . . . . . . . 5
5.6.
HEAT . . . . . . . . . . . . . . . . . . . . . . . 5
5.7.
COOL. . . . . . . . . . . . . . . . . . . . . . . 6
5.8.
OFF . . . . . . . . . . . . . . . . . . . . . . . 6
5.9.
DEFAULT PROGRAM . . . . . . . . . . . . 6
5.10.
HOLD. . . . . . . . . . . . . . . . . . . . . . . 6
5.11.
OVERRIDE . . . . . . . . . . . . . . . . . . . 6
5.12.
FAN MODES . . . . . . . . . . . . . . . . . . 6
5.12.1. AUTO . . . . . . . . . . . . . . . . . . . . . . . 6
5.12.2. ON. . . . . . . . . . . . . . . . . . . . . . . . . 6
5.12.3. CLEAN CYCLE™. . . . . . . . . . . . . . . 7
5.13.
DISPLAY ILLUMINATION. . . . . . . . . . 7
5.14.
AUDIBLE BEEP . . . . . . . . . . . . . . . . 7
6.
PROGRAMMING . . . . . . . . . . . . . . 7
6.1.
DEFAULT TEMPERATURE PROGRAM . 7
6.2.
EDITING HEAT OR COOL PROGRAMS 7
6.2.1. WEEKDAY PROGRAMMING. . . . . . . . 7
Mt. Laurel, New Jersey 08054, USA
www.luxproproducts.com
G
Easy as
HEAT
OFF
COOL
1–2–3
Thank you for your confidence in our product. To obtain the best
results from your investment, please read these instructions and
acquaint yourself with your purchase before installing your new
thermostat. Then follow the installation procedures, one step at a
time. This will save you time and minimize the chance of
damaging the thermostat and the systems it controls.
These instructions may contain information beyond that required
for your particular installation. Please save for future reference.
6.2.2. WEEKEND PROGRAMMING . . . . . . . 8
6.3.
CLEAN CYCLE™
(IAQ FAN PROGRAMMING) . . . . . . . . 8
6.4.
COPY . . . . . . . . . . . . . . . . . . . . . . . 9
7.
ADVANCED FEATURES. . . . . . . . . . 9
7.1.
KEYBOARD LOCK . . . . . . . . . . . . . . 9
7.2
FILTER MONITOR . . . . . . . . . . . . . . 9
7.2.1. FILTER USAGE . . . . . . . . . . . . . . . . 9
7.2.2. FILTER LIMIT . . . . . . . . . . . . . . . . . 9
7.3.
ENERGY USAGE . . . . . . . . . . . . . . . 10
7.4.
CALIBRATION OFFSET . . . . . . . . . . . 10
7.5.
RESET . . . . . . . . . . . . . . . . . . . . . . 10
7.5.1. HARDWARE RESET . . . . . . . . . . . . . 10
7.5.2. SOFTWARE RESET . . . . . . . . . . . . . 10
7.6.
TEMPERATURE VARIATION / SWING . 10
7.6.1. SWING 1 – 1st STAGE. . . . . . . . . . . 11
7.6.2. SWING 2 – 2nd STAGE . . . . . . . . . . 11
7.7.
DEAD BAND . . . . . . . . . . . . . . . . . . 11
8.
SET UP OPTIONS . . . . . . . . . . . . . . 11
8.1.
MINIMUM RUN TIME – J3 . . . . . . . . 12
8.2.
CLOCK FORMAT – J4 . . . . . . . . . . . 12
8.3.
TEMPERATURE DISPLAY FORMAT
(F/C DISPLAY) – J5 . . . . . . . . . . . . . 12
8.4.
SMART RECOVERY – J6 . . . . . . . . . 12
8.5.
FAN OVERRUN TIME – J7 . . . . . . . . 12
8.6.
REPOSITIONING JUMPERS. . . . . . . . 12
9.
BATTERIES/MAINTENANCE . . . . . . 12
9.1.
BATTERY INSTALLATION . . . . . . . . . 13
10.
TECHNICAL ASSISTANCE. . . . . . . . 13
11.
WARRANTY . . . . . . . . . . . . . . . . . . 13
12.
WIRING DIAGRAMS . . . . . . . . . . . . 14
13.
CROSS REFERENCE CHART . . . . . . 15
14.
SOFTWARE RESET TABLE . . . . . . . 16
15.
JUMPER AND SWITCH POSITIONS . 16
WARNING: Use Energizer
®
or DURACELL
®
Alkaline Batteries Only.
Energizer
®
is a registered trademark of Eveready Battery Company, Inc.
DURACELL
®
is a registered trademark of The Gillette Company, Inc.
43381

Advertisement

loading