INTRODUCTION

Rating Plate

When corresponding with the factory or your local
authorized factory service center regarding service problems
or replacement parts, be sure to refer to the particular unit
by the correct model number (including the prefi x and suffi x
letters and numbers) and the warranty serial number. The
rating plate affi xed to the unit contains this information.
The rating plate is visible by removing the lower front panel
on the G22 Series, the drip tray on the G24 Series or the valve
panel on the G20 Series.

INSTALLATION

General Information

1. Damage check: check carton or crate for possible damage
incurred in shipping. After carefully uncrating, check for
"concealed" damage. Report any damage immediately to
your carrier.
2. Carefully remove unit from carton or crate. Burner tie
wires and other packing material should be removed
from units. On stainless steel and brushed units, the
protective material covering the stainless steel should be
removed immediately after the unit is installed.
3. Remove valve panels, top grates or fry tank and place in a
safe area to prevent damage.
Part #4519655 Rev.2 (Jan 27/15)
We suggest installation, maintenance and repairs should be
performed by your local authorized service agency listed in
your information manual pamphlet.
In the event you have any questions concerning the
installation, use, care or service of the product, write or call
our Product Service Department.
This product must be installed by professional personnel as
specifi ed. Garland/U.S. Range products are not approved or
authorized for home or residential use, but are intended for
commercial applications only. Garland / U.S. Range will not
provide service, warranty, maintenance or support of any
kind other than in commercial applications.
4. Should it be necessary to remove the steel griddle plate
on units equipped with griddle thermostat, the griddle
thermostat bulb and capillary must fi rst be withdrawn
from the bulb shield assembly, located on the underside
of the griddle plate. This can be accomplished with the
griddle front raised and supported by the griddle prop
located on the underside of the griddle plate. Loosen the
four pal nuts securing the bulb shield assembly to the
griddle plate and withdraw the griddle thermostat bulb.
5. When a griddle plate is being installed on units equipped
with griddle thermostats, the thermostat bulb must
be inserted in the groove between the plate and the
bulb shield assembly. This can be accomplished with
the griddle front raised and supported by the griddle
prop, located on the underside of the griddle plate. It is
important for accurate temperature control that the bulb
be located inside the groove. Tighten the four pal nuts
securing the bulb shield assembly to the griddle plate.