8 Remove the six T20 Torx screws that attach the power supply unit to the printer,
disconnect the cables from it, and lift it away from the printer.
Note: When you remove the screws that attach the power supply unit to
the printer, the rear panel of the printer will detach.
Ground
cable
Screw
(6 places)
9
To replace the power supply unit, reverse Steps 1 through 8. You need to reuse
the ground (GND) cable (P/N 236-068-003) and the cooling plate
(P/N 1-206170-00).
Note: Make sure that you attach the GND cable through the lower left
screw when you replace the power supply unit.