Forced Mode; Protection Operations In Heat Mode - Technibel CWX3B5XAB Technical Data & Service Manual

Split system air conditioner
Table of Contents

Advertisement

4-7 Forced Mode

In this mode the system operates (COOLING or HEATING mode – fixed settings) or is switched off by
means of the MODE button of the indoor unit control board. The operation modes can be selected
pressing the button in a cyclic way (OFF
COOLING mode
SET POINT temperature = 25°C
FAN SPEED = HIGH
HEATING mode
SET POINT temperature = 21°C
FAN SPEED = HIGH

4-8 Protection operations in Heat Mode

5-8.1 Cold draft
This feature prevents the supply of cold air forcing the indoor fan to a speed which cannot be changed
by the user. As soon as the protection mode is exited speed can be changed manually through the
remote controller. The protection acts in the following
COOL
HEAT
OFF...). The settings are: