Event Buffer And "Real Time Clock; Programmable Outputs; Espload Upload/Download Software; Advanced Technology Zoning - Paradox Esprit 738 EXPRESS Installation Manual

Table of Contents

Advertisement

Event Buffer and "Real Time" Clock
Incorporation of a "real time" clock permits the creation of a 256 event, PC uploadable buffer with time
and date. Two automatic arming options are made possible by the inclusion of the "real time" clock.
Auto arming can be programmed to take place at a specific time, or following a set time period without
any zone activity (auto arm and/or report only).

Programmable Outputs

Almost any control panel status situation may be used to activate the Esprit's programmable outputs.
Once a panel status mode is selected for a PGM to follow, the polarity and duration of the output may
also be programmed. 18 supplementary programmable outputs are available with the SRI18 module,
which connects to the panel's serial output.

Espload Upload/Download Software

Espload upload/download software revolutionizes control panel supervision by offering powerful panel
programming, modification, real-time monitoring and data management tools. It functions with most
Hayes-compatible modems, requires only 2 minutes to perform a full upload or download, and is
extremely simple to learn and operate. (Upload/download software is not permitted on UL installations.)
Advanced Technology Zoning (738 only)
Advanced Technology Zoning was developed to permit connection of 2 zones and a tamper on a single
pair of wires, as well as providing wire fault recognition. ATZ simplifies the task of meeting the zone
requirements of any installation and, at the same time, reduces installation costs.
Alarm Relay (optional on the 738 EXPRESS)
Single pole, double throw dry contacts rated at 5 amps that follow the local alarm (bell/siren) output.

SPECIFICATIONS

Inputs and Outputs:

Maximum Zones:
639/640 LCD and 616/626/633 LED keypads:
(See "Keypad Connections", page 8.)
738 Express: 9 zones (7 onboard zones + 2 keypad zones)
738 : 14 zones (6 onboard zones + 6 ATZ zones including 2 keypad zones)
Zone Configuration: N.C. (no resistors), EOL (1 resistor), "Advanced Technology Zoning" (738 only) and
wire/tamper recognition using 1 resistors per zone. (Zone configuration address 088)
Battery Charger:
360mA with dynamic Battery test.
Aux power:
400 mA, Fuseless electronic shutdown at 1A, Automatic restore
Bell Out:
1A, Fuseless electronic shutdown at 3A, Automatic restore
AC input:
16.5 Vac, 40VA, 50 - 60Hz
PGM outputs:
More than 1000 options to follow
2 operation modes: Timed (1 sec.- 2 hrs.) or following predetermined condition.
N.C. or N.O to ground, 50mA
Can also be remote-controlled by PC using Espload.
Serial Data Output: (1200, 1, N) for use with accessory modules (not UL systems).

Event Buffer:

256 event buffer with time and date.

Operating Modes:

49 User codes (2 Master codes) 4 or 6 digit codes.
Partitioning to System "A", System "B", both systems (dual area), or no system assignment (common area).
Regular, "Stay" (at Home) arming, "Double Stay" (no delay) arming, Force "Away" arming.
Fast "One key Full Arm", "One key Stay Arm" and "One key Exit".
Key Switch Arm/Disarm ("stay" or "regular" mode).
PS1 bedside remote.
3 keypad-activated panic alarms.
Real Time Clock for "list of events", auto arming and test reports.
Auto arm on "time" or "no zone activity delay time".
*
*
Max. (
UL tested for 30mA only)