2
Parts Rating
2-1. Outdoor Unit (50Hz model: MMY-MAP
4HT8-E,
MAP
4HT8-TR, MAP
4HT8, MAP
4T8-SG)
Name
1 Compressor
1 Compressor
1 Compressor
1 Compressor
1 Compressor
2 4-way valve coil
3 Pulse motor valve coil
2-way valve coil
4
2-way valve coil
5
6 High-pressure SW
7 Pressure sensor (For high pressure) NSK-BC038F-067 0.5~4.3V/0~3.73MPa
8 Pressure sensor (For low pressure) NSK-BC010F-067 0.5~3.5V/0~0.98MPa
9 Fan motor
10 Case heater (For comp.)
11 Case heater (For accum.)
12 Fusible plug
Model
DA421A3FB-29M
Output: 2.3kW×2
DA421A3FB-29M
Output: 3.1kW×2
DA421A3FB-29M
Output: 4.2kW×2
DA421A3FB-29M
Output: 3.0kW×3
DA421A3FB-29M
Output: 3.6kW×3
STF
AC220-240V 50Hz
HAM-MD12TF-6
DC12V
VPV
AC220-240V 50Hz
SV2,SV3A,SV3B,SV3C,SV3D,SV3E
AC220-240V 50Hz
SV2,SV3A,SV3B,SV3C,SV3D,SV3E,SV3F,SV6
FQ-G593
AC220-240V 50Hz
SV41,SV42,SV5
AC220-240V 50Hz
SV41,SV42,SV43
ACB-4UB32W
OFF:3.73MPa ON:2.9MPa
STF-340A1000-1
DC280V/1kW
AC240V/29W
AC240V/55W
73°C
43