Fresh Air Intake Indoor Unit For S-Mms - Toshiba MMY-MAP0804HT8(Z)(ZG)-E Service Manual

Multi type heat pump model cooling only model
Table of Contents

Advertisement

1-2-16. Fresh Air Intake Indoor Unit for S-MMS

Model: MMD-AP0481HFE
WHI
BLK
1
3
1
1
3
3
RED ACIN
1
1
WHI
3
3
1
1
2
2
RED
WHI
RED
1
WHI
3
Connector
R(L)
S(N)
Indoor unit
earth screw
Power supply
220 – 240V ~ 50Hz
220V ~ 60Hz
Symbol
Parts name
FM
Fan Motor
RC
Running Capacitor
TR1
Transformer
TA
Intake air temp. sensor
TF
Blow temp. sensor
TC1, TC2, TCJ
Temp. sensor
RY005 ~ 007
Fan motor control relay
RY002
Drain control relay
PMV
Pulse Motor Valve
F1
Fuse for fan motor
43F1
Fan motor control relay
DP
Drin Pump motor
FS
Float Swotch
1.
indicates the terminal block.
Latter at inside indicates the terminal number.
2. A dotted line and broken line indicate the wiring at site.
3.
indicates the control P.C. board.
4. When installing the drain pump connect the froat switch connector to CN030 connector.
5.
A
position is connected to terminal block when change to static pressure.
Exchange the lead wire of arrow (
lead wire's color of fan motor.
8
7
RED
43F1
Surge absorber
Fan
CN083
7
(WHI)
9
7
5
3
1
RY007
H
M
L
P301
RY004
RY006
CN304 (GRY)
RY005
CN309 (YEL)
Fuse
T5.0A, 250V ~
CN067 (BLK)
CN044
CN040
CN041
CN066 (WHI)
(BRW)
(BLU)
(BLU)
1
2
1
2
1
2
1
2
1
EMG
BLU
BLU
BLK BLK
Line filter
A
U
U
1
2
U
U
1
2
A
Remote
Outdoor unit
controller
board
WHI
F1
RED
T10A, 250V ~
RED
RED
5
43F1
3
YEL
Closed-end
connector
Sold separately
) pisition after the terminal number as figure and
(Option)
DP
LM
CN033
DP
(GRN)
CN068
1
3
1
3
(BLU)
1
3
1
3
1
2 3
CN030
(RED)
UL
FS
RY002
RY001
Power
supply circuit
CN050
CN074
(WHI)
(WHI)
3
1
2
3
4
5
1
2
3
1
2
3
3
1
2
3
1
2
3
1
2
3
1
2
3
Sub P.C. board
MCC-1520
B
1
2
3
1
2
3
B
Remote controller
6
43F1
RC
4
1
2
3
4
A
4P (WHI)
1
2
3
4
Fan 1
BLU
1
2
3
4
4P (WHI)
1
2
3
4
BLU
FM
G & Y
Terminal block No.
F1 (Low static pressure tap)
F2 (Intermediate static pressure tap)
F3 (High static pressure tap)
F4
41
TA
TCJ
TC2
TC1
1
2
1
2
1
2
1
3
1
2
1
2
1
2
1
2 3
CN104
CN102
CN101
CN100
(YEL)
(RED)
(BLK)
(BRW)
Control P.C. Board
for Indoor Unit
MCC-1403
CN075
CN061
CN032
CN060
(WHI)
(YEL)
(WHI)
(WHI)
4
5
6
1
2
3
4
5
6
1
2
1
2
3
4
5
6
T10
Fan drive
Option
CN02
4
5
6
(YEL)
4
5
6
Fan motor inside wiring diagram
4
5
6
CN01
4
5
6
(WHI)
BLK
TR1
WHI
GRY
RED
Motor over heating protection switch
F
F
F
F
1
2
3
4
ORN
BLK
1
2
3
ORN
BLK
RED : RED
WHI : WHITE
YEL : YELLOW
BLU : BLUE
BLK : BLACK
GRY : GRAY
PNK : PINK
ORN : ORANGE
BRW : BROWN
G & Y : GREEN & YELLOW
Fan motor wiring
Blue (50/60Hz)
Orange (50/60Hz)
Bkack (50/60Hz)
TF
1
2
1
2
CN103
(GRN)
1
CN080
2
PNL
(GRN)
3
1
CN073
EXCT
(RED)
2
1
CN070
Filter
(WHI)
2
1
2
CN081
3
(BLK)
4
5
6
6
5
5
5
5
2
2
4
4
1
1
CN082
PMV
(BLU)
3
3
3
3
2
2
4
4
1 1
6 6
4
5
6
BLU
ORN
49F
Color Identification
Note
At shipment from factory

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mmy-map0804ht8(z)(zg)-trMmy-map1004ht8(z)(zg)-eMmy-map1004ht8(z)(zg)-trMmy-map1204ht8(z)(zg)-trMmy-map1404ht8(z)(zg)-trMmy-map1604ht8(z)(zg)-tr ... Show all

Table of Contents