Whirlpool AGB 483/WP Instructions For Installation, Use And Maintenance Manual page 10

Table of Contents

Advertisement

Model
Category
Construction type
Air necessary for combustion
Nominal thermal power
Minimum thermal power
Overall thermal power (gas)
AGB 499/WP
AGB 483 - 493 - 486 - 500/WP
AGB 491/WP
AGB 495/WP
AGB 489/WP
AGB 356/WP
AGB 492/WP
AGB 484/WP
AGB 494/WP
AGB 485/WP
AGB 490/WP
AGB 488/WP
AGS 775/WP
ADN 021/WP
ADN 019/WP
Connection pressure
Methane gas 2H
Liquid gas 3+
Gas connection values
Methane gas 2H
Liquid gas 3+
Nozzles Ø 1/100 mm
G20
Main burner
G30/31
No. of nozzles, pilot burner
Primary air distance "A"
Electrical data
Electric oven power:
GN 2/1 - 5.9 kW
GN 1/1 - 2.5 kW
064_03 - GAS KITCHENS
3 - TECHNICAL DATA
II2H3+
A
3
m
/h
kW
kW
Hour consumption
G20
G25
3
3
m
/h
m
/h
10.0
kW
1,06
-
20.0
kW
2,12
-
26.0
kW
2,75
-
28.0
kW
2,96
-
23.8
kW
2,52
-
12.0
kW
1,27
-
23.6
kW
2,50
-
27.8
kW
2,94
-
31.6
kW
3,34
-
35.8
kW
3,79
-
40.0
kW
4,23
-
16.0
kW
1,69
-
33.8
kW
3,58
-
20.8
kW
2,20
-
29.2
kW
3,10
-
G20
20 mbar
G30/G31
28/37 mbar
3
3
(HuB = 9.45 kWh/m
) in m
/h
(HuB = 12.87 kWh/kg) in kg/h
Nominal thermal power
Minimal thermal capacity
Nominal thermal power
Minimal thermal capacity
G20
G30/G31
Methane gas G20
Liquid gas G30/G31
Voltage:
V 400 3N 50 Hz / 230 3 50 Hz
230 50 Hz
TABLE 1
X
Y
Ø 100
Ø 120
8
12
4.0
6.0
1.2
1.8
G30/G31
kg/h
0,78
1,56
2,03
2,19
1,86
0,94
1,85
2,18
2,47
2,80
3,13
1,25
2,65
1,63
2,28
0.423
0.635
0.313
0.470
145
185
Adjustable
Adjustable
100
125
45
75
27
27
19
19
7
9
Open
Open
10 · 26
Solid
Gas oven
Gas oven
Gas range
GN 1/1
GN 2/1
16
7.5
16
8.0
3.6
7.8
5.5
0.75
-
0.847
0.381
0.825
0.626
0.282
0.611
200
155
215
-
Adjustable
Adjustable
140
100
140
60
48
-
35
-
35
25
-
20
12
Fix
Open
18
Fix
Open
No. of cables per section:
2
5 x 2.5 mm
/ 4 x 2.5 mm
2
3 x 1.5 mm
Gas oven
MAXI
24
12.0
-
1.270
0.939
270
-
170
-
36
19
3
Open
2
07/2007

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents