Bryant Geothermal Heat Pump Systems 50YEW Water-To-Water Design Features ® The 50YEW series is unlike any other water-to-water heat pump on • Puron HFC-410A zero ozone depletion refrigerant. the market today. The large operating map of the scroll compressor • Circuit breaker protected 75VA control transformer.
Page 4
Dual level compressor isolation and discharge muffl er for ultra quiet operation Hinged Front Access Door and Three Removable Panels For Ease of Installation and Service 12-Point Terminal Strip For Ease of Low Voltage Wiring 50YEW Bryant: Whatever It Takes.
Bryant Geothermal Heat Pump Systems Model Key 4 5 6 10 11 12 Y E W 0 1 0 3 1 1 Prefix Packaging 1 = Single Pack, Domestic Residential Series Revision Level YEW = Puron High Temperature Heating Only Water-to-Water...
Indoor temperature is also called “Load;” outdoor temperature is also called “Source.” Numbers shown with “/” indicate entering/leaving water temperatures. Bold outline indicates typical radiant fl oor application temperatures. Ratings at 40°C [104°F] are based upon AHRI/ISO Standard 13256-2; all other ratings are based upon Standard EN 14511-2. 50YEW Bryant: Whatever It Takes.
Page 8
Operation below 40°F EWT (source) is based upon 15% methanol antifreeze solution. All performance data is based upon the lower voltage of dual voltage units. Antifreeze for source water is required for operation in the shaded area and all source EWTs below 40°F. 50YEW Bryant: Whatever It Takes.
Bryant Geothermal Heat Pump Systems Physical Data Model Compressor (qty) Factory Charge HFC-410A (oz) [kg] 88 [2.50] Indoor/Load Water Connection Size FPT (in) Outdoor/Source Water Connection Size FPT (in) Domestic Hot Water Connection Size FPT (in) Maximum Working Pressure (Water Side)
(Indoor) Water Out Water In Voltage Voltage Supply Water In Water Out Water In Water Out 26.8 25.6 48.9 22.3 11.3 17.7 14.4 33.6 35.6 68.1 65.1 124.2 20.6 56.6 28.7 36.6 85.3 90.4 96.5 50YEW Bryant: Whatever It Takes.
Bryant Geothermal Heat Pump Systems Electrical Data Units with DHW Option Compressor ISBP Total Load Source Voltage Min/Max Model Voltage Pump Unit Circuit Fuse Pump Pump Code Voltage Amps HACR 1.07 1.07 22.8 50YEW010 THW010 208-230/60/1 197/254 20.7 1.07 1.07 1.07...
Thread) fi tting without the use of a back-up wrench. All Source heat exchangers and refrigerant suction lines shall be insulated to water piping shall be insulated to prevent condensation at low liquid prevent condensation at low liquid temperatures. temperatures. 50YEW Bryant: Whatever It Takes.
This mode shall include a factory-installed, internal secondary heat exchanger and a factory-installed potable Bryant residential class heat pumps are backed by a ten-year limited water, bronze circulating pump. This option shall provide an warranty on all unit parts, including the following accessories when additional set of water connections for the potable domestic installed with Bryant units: Flow Controllers &...