[A] Precaution when writing the data
Set the writing voltage (VID) to 3.3V.
When writing the data, set the address from 0 to 1FFFFF. The data may not be written correctly if it
is not set.
The Flash ROM in which the data will be written, on the download jig is selected by switching the
rotary switch on the adapter. Be sure to switch the rotary switch on the adapter depending on the
data (file) to be written.
Rotary Switch
1
2
3
4
5
6
Note:
Note:
Be sure not to confuse different ROM Versions since the file name is identical although the ROM
version is different.
6.1.3

K-PWA-DLM-320

It is feasible to update the firmware automatically by connecting the download jig to the ADF control PC
board and turning the power of the equipment ON.
< Procedure >
(1)
Turning OFF the power of the equipment and take off the ADF rear cover.
(2)
Connect the download jig with the connector (CN81) on the PC board.
(3)
While pressing [0] and [8] simultaneously, turn ON the power. (rewriting data starts)
(4)
During the data is rewritten, the LED on the download jig lights. When the data rewriting is com-
pleted, the LED blinks slowly (at an interval of 0.8 sec.). If the LED blinks fast (at an interval of
0.1 sec.), the rewriting has been failed.
(5)
Turn OFF the power of the equipment and remove the download jig.
(6)
Install the ADF rear cover.
* If rewriting data is failed, turn OFF the power and repeat the procedure.
Connector
Note:
Note:
Be sure to print out the list to confirm the firmware version for the ADF.
P. 2-11 "2.2.4 List Print Mode (9S)"