11

Heatronic settings

11.1 General information

The Heatronic unit enables easy setting and testing of a
large number of appliance functions.
For an overview of the service functions see
chapter 11.2 on page 44.
2
1
3
4
5
2
1
6
max
Fig. 43
Appliance controls
1
Chimney sweep button
2
Service button
3
Display
4
eco button or "Up" for service functions
5
Holiday button or "Down" for service functions
Selecting service functions
The service functions are subdivided into two levels
(
tables 15 and 16 on page 44).
B Press and hold the service button
up.
The display shows a code such as 1.A (service level 1).
B Press eco button and holiday button simultaneously
until a code such as 8.A appears (service level 2).
B Repeatedly press the holiday button or eco button
until the required service function is displayed.
B Press and release the chimney sweep button
The chimney sweep button
display shows the setting for the selected service
function.
Making a setting
B Repeatedly press the holiday button or eco button
until the required service function value is displayed.
B Enter the value on the "Heatronic settings" label
supplied and affix in a clearly visible position.
By using the "Heatronic settings" label, you
will make it easier for your contractor to set
modified service functions during servicing
at a later date.
3
reset
4
eco
5
3
4
e
2
1
6
max
min
6 720 644 143-11.1O
until it lights
.
will light up and the
Settings on the Heatronic
Service function
System installer:
6 720 644 145 (2010/09)
Fig. 44
Saving a setting
B Press and hold chimney sweep button
display shows
.
The unit automatically exits the service level
if no button is pressed for 15 minutes.
Exiting the service function without saving settings
B Briefly press the central heating boost button
The light in the central heating boost button
out.
Restoring standard settings
To restore all values from service levels 1 and 2 to the
standard settings:
B In service level 2, select service function 8.E and save
value 00. The appliance starts with the standard
setting.
Heatronic settings | 43