CEILING RINGS

The ceiling ring is to meet fire stop requirements.
Accessory Ceiling Ring (P/N 7660---2841) may be
used, (see Figure 10) or the mobile home manufactur-
er or the installer may use other approved methods to
stop fire.
If required, three (3) sections of Accessory Ring may be
used as shown in Figure 10B to provide closer clear-
ance around roof jack.
A
Figure 10 — Ceiling Rings
Sales Package
7681---6621
7681---6631
7681---6651
7681---6661
7681---6671
7681---6681
7681---6691
7681---6611
7681---6711
TEMPLATE & CUTOUT DIMENSIONS
14"
Duct Cutout
Dimensions
11--- 9/16"
13--- 9/16"
Figure 11 — Duct Connector Dimensions
TABLE 6 — Duct Connectors
Part Number
7681---602
2" Duct Connector — For Ducts 1---1/8" below top of floor surface
7681---603
3" Duct Connector — For Ducts 2---1/8" below top of floor surface
7681---605
5" Duct Connector — For Ducts 4---1/8" below top of floor surface
7681---606
6" Duct Connector — For Ducts 5---1/8" below top of floor surface
7681---607
7" Duct Connector — For Ducts 6---1/8" below top of floor surface
7681---608
8" Duct Connector — For Ducts 7---1/8" below top of floor surface
7681---609
9" Duct Connector — For Ducts 8---1/8" below top of floor surface
7681---611
11" Duct Connector — For Ducts 10---1/8" below top of floor surface
7681---612
12" Duct Connector — For Ducts 11---1/8" below top of floor surface
12"
NOTE:
Duct Connector may be used
positioned in any of four (4))
positions to fit duct.

DUCT CONNECTORS

The duct connector is designed for use on ducts down to
12" in width. When using the connector on smaller width
ducts, there will not be sufficient clearance to bend the tabs
on two sides of the duct connector.
In such cases the tabs may be attached to the sides of the
duct by using sheet metal screws or other suitable fasten-
ers. Holes for sheet metal screws are provided in three (3)
tabs on each side of the duct connector. If more than 3 tabs
B
need to be used to provide a more secure and air tight con-
nection, the remaining tabs can also be fastened to the
duct with screws after drilling the required screw holes.
If tape is used to provide a better air seal, it should be a type
approved by the applicable national or local codes.
1--- 13/16
1--- 15/16"
15--- 7/8"
23"
1"
13
Depth
15--- 7/8"
9--- 3/4"
Duct
Locating
Hole
Flue Center
Floor Cut--- out Line
Casing Front
Door Front
Figure 12 — Template
9--- 7/8"
12--- 1/4"