Download Print this page

Broan 744 Installation And Operating Instructions page 3

Recessed fan / light

Advertisement

3. Pound in nails.
Remove unit temporarily, and pound nails partially into joists at
all four marked locations.
4. Hang and secure housing.
Hang unit from nails. Check to make sure that there will be a 1/
8" gap between bottom of housing and ceiling material. Pound
nails tight. For wide joist centers: A #8 x 3/8 self-tapping screw
can be used to join extended brackets together and create a
rigid mount. To ensure a noise-free mount, crimp the bracket
channels tightly around mounting brackets.
FLUSH
5. Attach damper/duct connector.
Snap the damper/duct connector onto housing. Make sure that
tabs on the connector lock in housing slots. (Top of damper/duct
connector will be flush with top of housing.)
®
HORIZONTAL POWER
CABLE CONNECTION
6. Choose power cable direction.
Remove wiring plate. When re-attached, the wiring plate allows
the power cable to enter unit horizontally or vertically.
7. Connect wiring.
Unit can be wired from outside of housing as shown. Use UL
approved connectors to wire per local codes.
BLUE AND RED
TO BLACK
WHITE
TO
WHITE
WIRING PLATE
Fan and Light operated with single on/off switch
BLUE (FAN)
TO
BLACK
WHITE
TO
WHITE
WIRING PLATE
Fan operated with separate on/off switch.
Light operated with separate on/off switch
or dimmer switch.
MODEL 744
Page 3
VERTICAL
POWER
CABLE
CONNECTION
TOP / BACK
OF HOUSING
GROUND TO
WIRING PLATE
2-WIRE PLUS
GROUND
POWER
CABLE
TOP / BACK
OF HOUSING
RED (LAMP) TO RED
GROUND TO
WIRING PLATE
3-WIRE PLUS
GROUND
POWER
CABLE

Advertisement

loading