Burn Rates And Operating Effi Ciency - Quadra-Fire 57ST-ACC Owner's Manual

5700 step top wood stove series advanced combustion control installation and operation pedestal model leg model
Hide thumbs Also See for 57ST-ACC:
Table of Contents

Advertisement

R
J. Burn Rates and Operating Effi ciency
For maximum operating effi ciency
1. This appliance has a timer system (ACC) that operates
the appliance at its maximum effi ciency removing any
guess work for the homeowner. Follow the instructions
below for each burn rate for the Start-Up Air Control and
Burn Rate Air Control. Figure 11.1.
2. Burn dry, well-seasoned wood.
Burn Rates
1. Starting a Fire
Open both controls fully by raising the Burn Rate Air Con-
trol all the way up until it stops and slide the Start-up Air
Control back until it stops.
• The blower tends to cool the appliance. Leave the blower
off until the burn is well established, i.e., 30 minutes.
After loading the appliance with wood and starting the
fi re, set both controls to the desired setting by following
the burn rate instructions below.
2. High Burn Rate - Maximum Heat* - 30,000+ BTU/hr
• Raise the Burn Rate Air Control all the way up until it stops
(top marker) to a fully open position.
Slide the Start-Up Air Control all the way back until it stops
(HI marker) and leave it there.
• This setting over-rides the timer system (ACC) so you
must monitor the fi re closely while in this setting to avoid
overfi ring your stove.
3. Medium-High Burn Rate*
Raise the Burn Rate Air Control all the way up until it
stops (top marker) to a fully open position.
remain on.
Slide the Start-Up Air Control all the way back until it
stops (HI marker) and then pull forward until it stops.
• This activates the timer system (ACC).
4. Medium-Low Burn Rate* - 10,000 to 15,000 BTU/hr
• Raise the Burn Rate Air Control up to the bottom of the
middle marker and stop. Leave the blower off until the
burn is well established, i.e., 30 minutes.
• Slide the Start-Up Air Control all the way back until it
stops (HI marker) and then pull forward until it stops.
• This activates the timer system (ACC).
WARNING! Risk of Fire!
When set on High Burn Rate and over-riding the Automatic
Combustion Control system an overfi re situation can occur
and may result in a chimney fi re.
Overfi ring will void the stove warranty
November 28, 2011
-
15,000 to 30,000 BTU/hr
Blower may
.
5700 Step Top Wood Stove Series ACC
5. Low Burn Rate* - Below 10,000 BTU/hr
• Leave the Burn Rate Air Control at the bottom marker.
Leave the blower off until the burn is well established, i.e.,
30 minutes.
Slide the Start-Up Air Control all the way back until it
stops (HI marker) and then pull forward until it stops.
*NOTE: These are approximate settings, and will vary with
type of wood or chimney draft. Due to altitude and other
environmental circumstances, this operational information is
a guideline only.
HIGH
LOW
Low (Closed)
Burn Rate
Air Control
Start-Up Air
Control
After activating the timer (ACC), if the control is placed
within the rear air section on the label it will allow rear air
to enter the fi rebox. This will not interfere with the timer
gradually closing the front air channel in 25 minutes. If
control is set on "HI" it over-rides the timer (ACC).
Figure 11.1
7038-159D
Shown with Side
Shield Removed
High (Open)
Front Air Channel
Operated by Timer
Timer
Rear Air Channel
Operates independently
Timer Manual
from Timer
Shut-off
Page 11