OBSERVED PROBLEM
Pilot will not stay lit after
carefully following lighting
instructions.
Pilot lit but no flame on the
burner.
Frequent pilot outage problem.
POSSIBLE CAUSE
No gas supply or shut-off valve is
off.
Air in gas line.
Construction debris clogging pilot
orifice.
Low gas pressure.
Control valve knob is not on the
"PILOT" position.
Kinked pilot line.
Bad valve.
Bad thermocouple or loose
connection.
Wall switch wires defective.
Pilot flame maybe too low or
blowing (high) causing the valve
safety to drop out.
- 12 -
REMEDY
Check to see if you have gas
supply.
Hold regulator control valve in
the "PILOT" position for 2 or 3
minutes to purge air. If you smell
gas, stop and wait for a few
minutes before trying to light the
unit.
Remove debris and dirt. Inspect
and clean any other possible
obstructions.
Contact your gas supplier.
Refer to section on pilot lighting.
Have a qualified technician
replace pilot line.
Replace regulator valve (Refer to
Replacement Parts List).
Tighten thermocouple or replace.
Check electrical connections.
Clean and/or adjust pilot flame
for maximum flame impingement
on thermocouple.