Chicago Electric 69480 Owner's Manual & Safety Instructions page 17

10" 15 amp industrial table saw professional series
Table of Contents

Advertisement

Table Saw Overload Protection
1. The Table Saw is equipped with an Overload
Protector (5). If the motor shuts off or fails
to start due to overloading (cutting stock too
fast, using a dull Saw Blade, low voltage,
using the Table Saw beyond its capacity, etc.),
turn the Switch to its OFF position.
Maintenance and Servicing
Procedures not specifically explained in this manual must
be performed only by a qualified technician.
TO PrEVENT SErIOUS INJUry FrOM AccIDENTAL OPErATION:
Always disconnect the Table Saw from its electrical outlet before performing
any inspection, maintenance, or cleaning procedures.
TO PrEVENT SErIOUS INJUry FrOM TOOL FAILUrE:
Do not use damaged equipment. If abnormal noise or vibration
occurs, have the problem corrected before further use.
cleaning, Maintenance, and Lubrication
1. BEFOrE EAcH USE, inspect the general
condition of the tool. Check for loose screws,
misalignment or binding of moving parts, cracked or
broken parts, damaged electrical wiring, improper
mounting of the Saw Blade (73) and any other
condition that may affect its safe operation.
2. remove cut-off pieces and scraps from the Table
before starting the Table Saw. Switch off the tool.
While the Saw Blade is completely stopped; unplug
the machine, remove the Blade, and remove all
debris. With a brush, soft cloth, or vacuum, remove
all sawdust from the Table Saw.
Allowing sawdust, scraps, or other debris
to accumulate can cause a fire, resulting in
severe personal injury or property damage.
3. Do not use solvents to wipe off the Table Saw, as
damage may result. If necessary, wipe with a damp
cloth. You may use a mild detergent.
Do not introduce water into the electric
motor through the motor vents.
4. Once clean, lubricate all moving parts with a light oil.
ITEM 69480
For technical questions, please call 1-888-866-5797.
2. Let the motor cool three to five minutes before
pushing the Reset button. This will reset
the overload device. The motor can then
be turned on again in the usual manner.
5. When storing, keep the Table Saw
covered with a cloth cover.
6. WArNING! If the supply cord of this power
tool is damaged, it must be replaced only
by a qualified service technician.
7. Use the Adjustable Stop Bolts in the table
top to adjust the zero degree and 45 degree
positive stops. A 5mm hex key and a
10mm wrench (both sold separately) are
required for adjustment. See Figure X.
Adjustable
Stop Bolts
Figure X