Comfort Valve System Control Sequence Of Operation With Transmitter
Figure 43
Step 6. INSTALLING CERAMIC PANEL,
LOGS AND GLOWING EMBERS
The packaged logs are located within the
firebox. The glowing embers are packaged
separately in plastic bags located in the
control area of the fireplace. Refer to the Log
Placement Guide for detailed placement in-
structions for ceramic panel, logs and glow-
ing embers (rockwool).
Step 7. CHECKING APPLIANCE OPERATION
With gas line installed run initial system check-
out before closing up the front of the unit.
Follow the pilot lighting instructions pro-
vided in the Homeowner's Care and Opera-
tion Instructions. For piezo ignitor location
see Figure 44 .
24
Note: Instructions are also found on the litera-
ture tag attached to the gas valve train.
When first lighting the appliance, it will take a few
minutes for the line to purge itself of air. Once
purging is complete, the pilot and burner will light
and operate as indicated in the instruction manual.
Subsequent lightings of the appliance will not re-
quire such purging. Inspect the pilot flame (remove
logs, if necessary, handling carefully).
Honeywell RF Control Millivolt Appliance
Pilot Checkout
Pilot Inspection
To obtain proper operation, it is imperative that
the pilot and burner's flame characteristics are
steady, not lifting or floating ( see Figure 45 ).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
Honeywell
Gas Valve
Piezo
Ignitor
Honeywell RF Control Millivolt Gas Valve
Showing Piezo Ignitor Location
Figure 44
Typically, the top 3/8" of the thermopile should be
engulfed in the pilot flame ( Figure 45 ).
To adjust pilot burner; (by a qualified service
technician), refer to Figure 39.
1. Remove pilot adjustment screw cap.
2. Adjust pilot screw to provide properly sized
flame.
3. Replace pilot adjustment screw cap.
The primary air shutter is set at the factory and
should only be adjusted, if necessary, by a
qualified service technician.
MILLIVOLT HONEYWELL
Thermopile
Ignitor Rod
³⁄₈" Min
Hood
(9 mm)
Pilot
Nozzels
Thermopile
Figure 45
Step 8. INSTALLING THE GLASS DOOR
Retrieve the glass door. Visually inspect the
gasket on the backside of the frame. Gasket
surface must be clean, free of irregularities
and seated firmly.
³⁄₈" Min