3.3.13 LF Motor
(1)
Remove the printhead (see 3.3.1).
(2)
Remove the ribbon protector (see 3.3.2).
(3)
Remove the pull-up roller Assy (see 3.3.3).
(4)
Remove the upper cover (see 3.3.4 (1) – (5)).
(5)
Remove the platen Assy (see 3.3.11).
(6)
Remove the driver board (see 3.3.12).
(7)
Remove the left FG plate 1.
(8)
Release the lock A to remove the LF motor 2.
(9)
To install, follow the removal steps in the reverse order.
Remark on assembly:
(1) Press the LF Motor Cable with a portion A of the Motor Plate.
Lock A
1
42113901TH01 Rev.3
2
A
Oki Data CONFIDENTIAL
69 /