Aprilaire 1510 Installation Instructions

Aprilaire 1510 Installation Instructions

Media air cleaner
Hide thumbs Also See for 1510:

Advertisement

Quick Links

WARNING
1. High voltage may cause serious
injury from electrical shock.
Disconnect power to the
furnace/air handler before
starting installation.
2. Sharp edges may cause injury
from cuts. Use care when cutting
and handling sheet metal.
SPECIFICATIONS
Model
Airflow Capacity
Replacement Media
Max. Equipment Weight
Air Cleaner Operating Environment
DIMENSIONS
B
without door
C
A
Model
A
1510
28-3/4
1. To prevent component failure, do not install the air cleaner on the warm
air supply or in an area where the temperature may exceed 140°F. This
may include areas above heat exchangers in downflow furnaces or above
exhaust flues in lowboy furnace cold air returns.
2. Installation must be done by a qualified heating and air conditioning
professional. Read instructions thoroughly before beginning installation.
3. Do not install air cleaner downstream of a UV light. UV lamps will cause
degradation of the filtering media.
1510
up to 3000 CFM maximum
Model 510 or 513 with SelfSeal
Cabinet will support 400 lb. static load
Temperature: 0°F – 140°F. Humidity: 0 – 90% non-condensing.
D
TABLE 1 – Dimensions (inches)
B
C
28-1/16
23-7/8
6-3/4
Model 1510 Media Air Cleaner
Installation Instructions
CAUTION
D
E
F
30-1/16
23-7/8
E
with door
F
G H
90-1333
G
H
28-3/4
31

Advertisement

loading

Summary of Contents for Aprilaire 1510

  • Page 1 Model 1510 Media Air Cleaner Installation Instructions WARNING CAUTION 1. High voltage may cause serious 1. To prevent component failure, do not install the air cleaner on the warm injury from electrical shock. air supply or in an area where the temperature may exceed 140°F. This...
  • Page 2 INSTALL THE AIR CLEANER CABINET LOCATING THE AIR CLEANER 1. Leave sufficient space in front of the air cleaner for the removal of the filtering media (see Figure 1). 2. DO NOT INSTALL DOWNSTREAM OF A UV LIGHT. UV lamps will cause degradation of the filtering media. 3.
  • Page 3 INSTALLATION 1. Disconnect power to the furnace or air handler at the electrical FIGURE 3 service panel. WARNING 120 Volts may cause serious injury from electrical shock. Disconnect power to the furnace/air handler before starting installation. Leave power disconnected until installation is completed.
  • Page 4 P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • www.aprilairepartners.com 10010397 6.13 Printed in U.S.A. B2701303A © 2013 Aprilaire – A division of Research Products Corporation...