Installation Of Indoor Unit; Installation Of Drain Hose - C&H CH-S09FTXS-B Owner's Manual

Split air conditioner design inverter series (arctic)
Table of Contents

Advertisement

Installation of Indoor Unit

1. Mounting plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way
type, during installation, the indoor unit should slightly slant to water tray's outlet for smooth drainage of
condensate.
2.Fix the mounting plate on the wall with screws.
3.Be sure that the mounting plate has been fixed firmly enough to withstand about 60 kg. Meanwhile, the
weight should be evenly shared by
09 12K UNIT:
131
Ø55
256.8
100
1.Slant the piping hole (
outdoor side.
2.Insert the piping-hole sleeve into the hole to prevent the connection piping
and wiring from being damaged when passing through the hole.
Connect the drain hose to the outlet pipe of the indoor unit.
1.
Bind the joint with rubber belt.
2.
Put the drain hose into insulating tube.
3.
Wrap the insulating tube with wide rubber belt to prevent
the shift of insulating tube. Slant the drain hose downward
slightly for smooth drainage of condensate.
Note: The insulating tube should be connected reliably with
the sleeve outside the outlet pipe. The drain hose should be
slanted downward slightly, without distortion, bulge or
fluctuation. Do not put the outlet in the water.
Installation of Mounting Plate
each
screw.
845
542
275
Ø55
50
50
124
Drill Piping Hole
55) on the wall slightly downward to the
Ф

Installation of Drain Hose

18K UNIT:
189
Fig.5
bulge
25
1018
685
575
55
55
99
99
65
Outdoor
Indoor
Wall pipe
Seal pad
outlet pipe of
rubber belt
outlet pipe of
indoor unit
drain hose
outlet pipe of
drain hose
indoor unit
rubber belt
insulating tube
rubber belt
outlet pipe of
indoor unit
insulating tube
connected
distortion
Flooded
Ø
55
indoor unit