ADC 6015 Instruction Manual

ADC 6015 Instruction Manual

Digital wrist automatic blood pressure monitor
Hide thumbs Also See for 6015:

Advertisement

Digital Wrist
Blood Pressure
Monitor
Automatic Blood Pressure Monitor
PLEASE NOTE:
THIS MEDIC L INSTRUMENT MUST BE
USED
CCORDING TO INSTRUCTIONS
TO ENSURE CCUR TE RE DINGS.
Questions?
Call DC toll free at 1-800-232-2670
6015
Instruction Manual

Advertisement

Table of Contents
loading

Summary of Contents for ADC 6015

  • Page 1 Digital Wrist Blood Pressure Monitor Automatic Blood Pressure Monitor 6015 Instruction Manual PLEASE NOTE: THIS MEDIC L INSTRUMENT MUST BE USED CCORDING TO INSTRUCTIONS TO ENSURE CCUR TE RE DINGS. Questions? Call DC toll free at 1-800-232-2670...
  • Page 2: Electromagnetic Interference

    1. Introduction 1.1. Features of your blood pressure monitor This blood pressure monitor, with integrated time/date display, is a fully automatic, digital blood pres- sure measuring device for use on the wrist. It enables very fast and reliable measurement of the systolic and diastolic blood pressure as well as pulse by way of the oscillometric method of measuring.
  • Page 3 evaluated after consultation with your doctor. NOTE: To obtain the greatest accuracy from your blood pressure instrument, it is recommended that the instrument be used within a temperature range of 50°F (10°C) to 104°F (40°C), with a relative humidity range of 15-90% (non-condensing). 3.
  • Page 4: Eating Habits

    Further information • If your values are mostly standard under resting conditions but exceptionally high under con- ditions of physical or psychological stress, it is possible that you are suffering from so-called “labile hypertension”. Please consult your doctor if you suspect that this might be the case. Warning: •...
  • Page 5: Inserting The Batteries

    4. omponents of your blood pressure monitor Your DC ® wrist type blood pressure monitor consists of: Time & Date/Time Date button Systolic Pressure Memory button Diastolic Pressure Pulse Battery Cover Start/Stop button Wrist Cuff Cuff fits wrist size 5½” to 7¾” inches. 5.
  • Page 6 ensure correct placement. See + and - symbols inside battery compartment. Note: You must set the current time and date after inserting the batteries, and each time you re- move the batteries. 5.2. Checking the current time/date/year setting Press and hold the Date/Time button. The date and time will be displayed. 5.3.
  • Page 7: Common Sources Of Error

    9) Press the DATE/TIME button again. The last two characters (min- utes) now blink. 10) The exact time (minutes) can now be entered pressing the MEMORY button. 11) Now after all settings have been made, press the TIME button once again.
  • Page 8: Discontinuing A Measurement

    c) Secure the cuff with the hook and loop adhesive so that it lies comfort- ably and not too tight. It should be comfortable. d) Lay your arm on a table with your palm upwards. Support your arm with a cushion so that the cuff rests at about the same height as the heart. Remain still for 2 minutes, sitting quietly, before beginning a measurement.
  • Page 9: Clearing The Memory

    15mmHg, and/or you hear irregular pulse tones on several occasions, please consult your doctor. Consult ADC® if your monitor seems to be defective. Never attempt to repair the instrument yourself! Any unauthorized opening of the instrument invalidates all warranty claims! 8.
  • Page 10: Warranty

    Never open the device! This will invalidate the manufacturers warranty! 9. Warranty Your ADC® blood pressure monitor is guaranteed for 5 years against manufacturers’ defects for the original purchaser only, from date of purchase. The warranty does not apply to damage caused by improper handling, accidents, professional use, not following the operating instructions or alterations made to the instrument by third parties.
  • Page 11 Inspected in the U.S. . Made in China 55 Commerce Drive tel: 631-273-9600, 1-800-232-2670 Hauppauge, NY 11788 fax: 631-273-9659 U.S. . www. dctod y.com DC (UK) Ltd. em il: info@ dctod y.com Unit 6, PO14 1TH United Kingdom IB p/n 93-6015-00 rev 6 english...