Water Piping System; Piping Installation - Kenmore Elite 153.321161 Use & Care Manual

Hybrid electric water heater
Table of Contents

Advertisement

Water Piping System
Water
temperature
over
125°F
(52°C) can cause severe
burns
instantly resulting in severe injury
or death.
Children,
the
elderly,
and
the
physically
or mentally
disabled
are at highest riskfor scald injury.
Feel
water
before
bathing
or
showering.
Temperature
limiting valves
are
available.
Read instruction
manual for safe
temperature setting.
Piping, fittings, and valves should be installed according to the
installation drawing (Figure 10). If the indoor installation area
is subject to freezing temperatures,
the water piping must be
properly insulated.
The water supply pressure should not exceed 80 psi. If this
occurs, a pressure reducing valve with a bypass should be
installed in the cold water inlet line. This should be placed on
the supply to the entire house in order to maintain equal hot and
cold water pressures.
IMPORTANT:
Heat must not be applied
to the water fittings
on the
heater as they may contain
nonmetallic
parts. If solder
connections
are used, solder
the pipe to the adapter
before attaching
the adapter to the hot and cold water
fittings.
Always
use
a
good
grade
of
joint
compound
and
be
certain
that
all
fittings
are
tight.
IMPORTANT:
DO NOT over apply joint compound.
Piping installation
NOTE: To protect against untimely corrosion of hot and cold
water
fittings,
it is strongly
recommended
that di-electric
unions
or couplings be installed on this water heater when
connected to copper pipe.
1.
Install the water piping and fittings as shown in Figure 10.
Connect the cold water supply (3/4" NPT) to
the
fitting
marked "Cold". Connect the hot water supply (3/4" NPT)
to the fitting marked "Hot".
2.
The installation of unions in both the hot and cold water
supply lines are recommended for ease of removing
the
water heater for service or replacement.
3.
Some local codes may require, and the manufacturer
of
this water heater recommends,
installing a mixing valve
or an anti-scald device in the domestic hot water line as
shown in Figure 10. These valves reduce the point-of-use
temperature
of the hot water by mixing cold and hot water
and are readily available. Contact a licensed plumber or
the local plumbing authority for more information.
4.
Some local codes
may require,
and the manufacturer
of this water heater recommends,
installing a pressure
reducing valve (PRV) in the cold water inlet line where it
enters the residence as shown in Figure 10.
5.
If installing the water heater in a closed water system,
install an expansion tank in the cold water line as specified
under "Closed System/Thermal
Expansion."
6.
Install a shut off valve in the cold water inlet line. It
should be located close to the water heater and be easily
accessible. Know the location of this valve and how to shut
off the water to the heater.
7.
Install a discharge line from the temperature and pressure
relief valve in the opening marked "T & P RELIEF VALVE".
See Figure 12 and the "Temperature and Pressure Relief
Valve" section.)
Massachusetts:
Install a vacuum
relief in J
cod water
ne per secton
19 MGL 142.
_ptional
Heat Trap Piping
J_
Union
Temperatpressure
......
Relief dvatve
!
_,_-
Shut-eft Valve (Hot)
_
c_"_
Untempered
Water
Outlet
i
'Outlet_
/
;Mixing Valve - Follow the Mixing Valve's
'
'
[
Manufacturer's
installation
Instructions.
"q
(Setto
120 ° F)
Discharge
Pipe
---czz
Tempered Water to Fixtures
(Do Not Cap or Plug)
I
._ !
Condensate
Drain Lines*
_
_
_2ZZZZZZZI_CoId
Water Outlet
DepthMetal
Drain Pan 2 1/2
Ill
_
/il
_
__22----2222-C_
In a closed system,
use a
Maximum
and
i
thermal
expansion tank.
See "Closed
System/
2 Inches wider than
,
L_ UL Cold
\
Thermal
Expansion"
the water heater.
_,_
L_
(Inlet). k
section.
_
(Cold)
Drain Line 3/4 "j
/
6" Maximum
ID Minimum
Drain
Air Gap
* If an adequate drain is not available
for the condensate
drain lines then a condensate
pump must be used. DO NOT discharge
the condensate
drain
lines into the metal drain pan.
Vacuum
Relief Valve
_L....-(when required
by local code)
:2_"_
Cold Water
_--2
j_.lnlet
Valve
-T--2-_-_ZZZZZ_,_.
Cold Water
_X
inlet
Pressure Reducing Valve (PRV)
should
be installed where the water
supply enters the residence.
When installed PRVs create a
closed water system,
a thermal
expansion
tank must be installed.
FIGURE 10.
12