LG DLG5988WM Service Manual page 16

Electric & gas dryer
Hide thumbs Also See for DLG5988WM:
Table of Contents

Advertisement

Component
7. Heater
8. Thermistor
9. Motor
10. Gas valve
valve 1
valve 2
11. Igniter
12. Frame Detect
Test Procedure
Measure resistance of the
following terminal
Terminal : 1 (COM) - 2
Terminal : 1 (COM) - 3
Terminal : 2 - 3
Measure resistance of terminal
to terminal
Temperature condition :
58°F ~ (10~40°C)
58°F ~ 104F (10~40°C)
Measure resistance of the
following terminal
Valve 1 terminal
Valve 2 terminal
Measure resistance of terminal
to terminal
Measure resistance of terminal
to terminal
Open at 370°F ((Maximum)
Close at 320°F
Check result
Resistance value : 10Ω
Resistance value : 10Ω
Resistance value : 20Ω
Resistance value : 10Ω
Resistance value : > 1.5kg ~
Resistance value :
> 1.5~2.5kg
Resistance value : 100~800Ω • Gas type
Resistance value
Resistance value < 1Ω
15
Remark
• Electric type
• Heater case -
Hi limit
• Electric type
• See Page 13
• Gas type
• Gas type

Advertisement

Table of Contents
loading

Table of Contents