Operating Tips; Operation And Performance - Fujitsu AWT14RB Operating Manual

Ceiling wall type room air conditioner
Table of Contents

Advertisement

TROUBLESHOOTING
Instructions relating to heating (*) are applicable only to "HEAT & COOL MODEL" (Reverse Cycle).
CHECK ONCE
Doesn't operate at all:
MORE
Poor Cooling
(or *Heating)
performance:
The unit operates
differently from the
remote control unit's
setting:
If the problem persists after performing these checks, or if you notice burning smells, or the TIMER indicator lamp (Fig.3 6)
flashes, immediately stop operation, disconnect the power supply, and consult authorized service personnel.

OPERATING TIPS

Operation and Performance

*Heating Performance
G This air conditioner operates on the heat-pump principle,
absorbing heat from outdoor air and transferring that heat
indoors. As a result, the operating performance is reduced
as outdoor air temperature drops. If you feel that insuffi-
cient heating performance is being produced, we recom-
mend you use this air conditioner in conjunction with
another kind of heating appliance.
G Heat-pump air conditioners heat your entire room by
recirculating air throughout the room, with the result that
some time may be required after first starting the air con-
ditioner until the room is heated.
*When Indoor and Outdoor Temperatures are High
When both indoor and outdoor temperatures are high dur-
ing use of the heating mode, the outdoor unit's fan may stop
at times.
Symptom
G Has there been a power failure?
G Has a fuse blown out, or a circuit breaker been tripped?
G Is the timer operating?
G Is the air filter dirty?
G Are the air conditioner's intake filter or outlet port blocked?
G Did you adjust the room temperature settings (thermostat) cor-
rectly?
G Is there a window or door open?
G In the case of Cooling operation, is a window allowing bright sun-
light to enter? (Close the curtains.)
G In the case of Cooling operation, are there heating apparatus and
computers inside the room, or are there too many people in the
room?
G Are the remote control unit's batteries dead?
G Are the remote control unit's batteries loaded properly?
Items to check
*Microcomputer-controlled Automatic Defrosting
When using the Heating mode under conditions of low
outdoor air temperature high humidity, frost may form on
the outdoor unit, resulting in reduced operating perform-
ance.
In order to prevent this kind of reduced performance, this
unit is equipped with a Microcomputer-controlled Automatic
Defrosting function. If frost forms, the air conditioner will
temporarily stop, and the defrosting circuit will operate
briefly (for about 7 to 15 minutes).
During Automatic Defrosting operation, the OPERATION
indicator lamp (red) will flash.
*Low Ambient Cooling
When the outdoor temperature drops, the outdoor unit's fans
may switch to Low Speed.
See Page
8 to 9
5
14