General Information
1-3
Relative Humidity: 20% to 80% with maximum wet bulb temperature not to exceed 29.4°C
(85° F)
Altitude: 0 to 4572M (0 to 15000 feet)
Storage Limits
Temperature: - 41 ° C to 71 ° C ( - 40.5° F to 159.8° F)
Relative Humidity: 20% to 80% with maximum wet bulb temperature not to exceed 29.4° C
(85° F)
Alignment Limits
Radial Alignment: 1.1 mils maximum of track center at track 16 measured at 20° C (68° F)
and 50% humidity.
Azimuth: 18° maximum clockwise or counterclockwise on tracks 16 and 34.
Power Requirements:
+
12VDC
±
0.6V
@
900ma nominal
+
5VDC ± 0.25V
@
600ma nominal
Media Life
Revolutions 2,500,000 revolutions on any track.
Head Life: More than 15,000 hours of operation with
HP
media.
Physical Dimensions and Weight
Figure 1-1 illustrates the physical dimensions.
Weight: 2.04Kg (4.5 lbs)
Height: 85.85mm (3.38 inches)
Width: 149.1mm (5.87 inches)
Length: 203.2mm (8 inches)
Performance Specifications
Soft Read Errors: 1 in 10
9
bits read on inner most track
Seek Errors: 1 in 10
6
seeks
See the 9130K Specification Document for further details.
"Hard Error" is defined as an error that cannot be recovered from using an
HP
approved
retry scheme.