12
E.5
Channel Configuration for ETSI ISDN
In the two-port SP201-SA, perform the following procedure once for trunk 2. In the four-port SP201-SA,
perform the procedure once each for trunks 3 and 4.
Note: If you are performing this procedure on a two-port SP201-SA, read trunk 3 as trunk 2.
What the terminal displays
user>
The following is the present Trunk
configuration.
If a change to the Timeslot or
Interface Type is desired
Enter the Trunk number you wish to
modify or exit:
Trunk
Signaling
Type
-------------------------------------------------------------------------
3
D
4
D
ISDN Trunk Number
Enter value(3 - 4) or "exit" :
Select interface type - user(0) or
network(1) : <current=1>
ISDN Interface number 1 assigned to
Trunk p ,
with a D Channel on timeslot 16.
Change ISDN Signaling Channel
Enter value(1 - 31; current="16") or
"exit" :
(The following message appears only if you change
the channel number used as the signaling timeslot.)
Changes applied
The card must be reset for the
changes to operate properly
Do you wish to reset now (y/n)?
not resetting...
user>
What you type
config dchans
Timeslot
Trunk
Type
16
E1
16
E1
p
where p is the port
number (3 or 4)
1 (or 0)
16
n
SP201-SA™ Installation Guide
What you are configuring
ISDN signaling channel
Link
Interface
State
Type
Inactive
Network
Inactive
Network
ISDN trunk p
SP201-SA as the Network role
(or as the User role) in this

ISDN connection

Signaling timeslot
Delay in implementation of
changes until performing a
warmstart (described in
Section F, SP201-SA
Warmstart)
(ISDN signaling has been
configured on this trunk.)
Protocol
ETSI ISDN
ETSI ISDN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Signalpath 201-sa

Table of Contents