Service And Adjustment; Temperature Regulation; Thermostat; Temperature Settings - Kenmore 153.326164 Use & Care Manual

30 / 38 gallon short
Table of Contents

Advertisement

Temperature
Regulation
IF I m7_,1 [el=1 r,t
Water
temperature
over
125°F
(52°C) can cause severe
burns
instantly resulting in severe injury
or death.
Children,
the
elderly,
and the
,_
physically
or mentally
disabled
..,--,_
_
are at highest riskfor scald injury.
Feel
water
before
bathing
or
showering.
Temperature
limiting valves are
available.
Read instruction
manual for safe
,,
temperature setting
HOTTER WATER CAN SCALD: Water heaters are intended
to produce hot water. Water heated to a temperature
which
wilt satisfy clothes washing, dish washing, and other sanitizing
needs can scald and permanently injure you upon contact. Some
people are more likely to be permanently
injured by hot water
than others. These include the elderly, children, the infirm, or
physically/mentally
handicapped.
If anyone using hot water in
your home fits into one of these groups or if there is a local code
or state law requiring a certain temperature water at the hot water
tap, then you must take special precautions. In addition to using
the lowest possible temperature
setting that satisfies your hot
water needs, some type of tempering device, such as a mixing
valve, should be used at the hot water taps used by these people
or at the water heater. Mixing valves are available at plumbing
supply or hardware stores. Follow manufacturers instructions for
installation of the valves, Before changing the factory setting of
the thermostat see Temperature Settings table at right.
Never allow small children to use a hot water tap, or to draw
their own bath water. Never leave a child or handicapped person
unattended in a bathtub or shower.
Thermostats
The thermostats
of this water heater have been factory set at
a position which approximates
120°F (49°C), to reduce the risk
of scald injury.
The upper
thermostat
is factory
set at a position
which
approximates
120°F (49°C) and is adjustable if a different water
temperature is desired. Read all warnings in this manual and on
the water heating before proceeding.
The lower thermostat
is factory
set at a position
which
approximates 120°F (49°C), and is adjustable if a different water
temperature
is desired. Read all warnings in this manual and on
the water heating before proceeding.
TEMPERATURE
ADJUSTMENT
KNOB
ADJUSTABLE
LOWER
THERMOSTAT
(FOR
DUAL
ELEMENT
MODELS)
ADJUSTABLE
LOWER
THERMOSTAT
WITH
HIGH
LIMIT
FIGURE 26.
Temperature
Settings
Table 1 :
110
(normalshowertemp.)
116
(pain threshold)
116
35 minutes
45 minutes
122
1 minute
5 minutes
131
5 seconds
25 seconds
140
2 seconds
5 seconds
149
1 second
2 seconds
154
instantaneous
1 second
(U.S. Govemment Memorandum,
C.P.S.C., Peter L. Armstrong, Sept. 15,1978)
NOTE: Water temperature
range of 120°m140°F
(49°-60°C)
recommended
by most dishwasher manufacturers.
Upper
and Lower Thermostat
Adjustments
(Refer to thermostat illustrations under "Thermostat" section)
THERMOSTAT
BEHIND
UPPER
ACCESS
PANE l
4
PANEL
(DUAL
ELEMENT
@_/%,_,._
[_
MODELS
ONLY)
FIGURE 25.
• Before
removing
any access
panels or servicing the water
heater, make sure the electrical
supply to the water heater is
turned "OFF".
• Failure to do this could result in
death, serious bodily injury, or
property damage.
NOTE:
It is not necessary
to adjust the upper thermostat.